Guides

Dell PowerEdge R740 parts: CPU, memory, PERC, caddies

An R740 is 14G and LGA3647. A Gold 6330, an H755, and a 13G caddy belong in other chassis. DIMM order, the H740P supercap, and the DXD9H tray decide the order.

An R740 on the bench is a 14G 2U with two sockets. Both sockets are LGA3647. The CPUs that belong in them are 1st Gen Xeon Scalable and 2nd Gen. The list stops there. A Gold 6330 is 3rd Gen, on LGA4189, and it belongs in an R750. We sell used R740 parts from Hong Kong against the chassis you already own. The service tag on the ear comes before the core count on the listing.

In late 2026 a new rack is often an R760, LGA4677 and DDR5, or a later PowerEdge built for Xeon 6. The R740 is still the machine a lot of people are filling, because the backplane, the iDRAC9, and the rails are already paid for. A newer CPU does not move this socket. A 4th Gen Gold 6430 and a 5th Gen part such as a Gold 6526Y are 16G CPUs. Xeon 6, and the MRDIMM modules that go with the high-core parts, sit in a later chassis again. None of those chips drop into this ILM.

The R750 is the next socket

The R750 is 15G. The CPU is 3rd Gen Xeon Scalable, Ice Lake, on LGA4189. Memory is still DDR4, and the channel count steps from six to eight, up to 3200, with PCIe 4.0. A Gold 6330 and a Gold 6348 fit that board. A Gold 6248 fits the R740. The bezels photograph alike from the front of the rack. The ear does not say the same model, and iDRAC prints the product name on the System page. If that name says R750, stop ordering LGA3647 chips for it.

The failure mode is mechanical. LGA4189 does not seat in LGA3647. The pad map is different, and forcing the chip bends pins in a socket you still needed. People order the 6330 because a title said Xeon Gold for a Dell 2U and the core count was higher. Higher cores on the wrong socket is a dead board, and the return shipping is slower than reading the ear. The same trap runs the other way. An H740P mini pulled from this chassis has nowhere to sit in an R750. 15G moved the controller to a front carrier. The card for that bay is an H755 or an HBA355, and the caddy, the power supply shell, and the BOSS module moved with it.

An R740xd is the same socket in a different storage chassis. Eight 3.5-inch bays or sixteen 2.5-inch bays is the plain R740. Twenty-four 2.5-inch, or twelve 3.5-inch plus a mid bay, is the xd. The CPU rules do not change. The backplane, the cable count, and the number of controllers do. Ordering "R740 parts" from a photo of an xd lid is how a single H740P shows up for a cage it cannot see.

AMD PowerEdge boxes of these years are their own ears. An R7425 is EPYC on SP3, DDR4, a 14G chassis that is not this Intel board. An R7525 is the 15G AMD box, Rome and Milan, still SP3. An R7625 is 16G: Genoa, and Bergamo on the density SKUs, socket SP5, DDR5. Turin, EPYC 9005, uses SP5 as well and belongs in a later platform. A Gold 6248 does not fit any of them, and an R740 heatsink does not bolt to those coolers. If the ear says R7425, this page is the wrong shopping list.

CPUs that post, and the BIOS in front of them

1st Gen is Skylake-SP. The pulls we see every week are the Silver 4114, 10 cores at 85W, the Gold 6130, sSpec SR3B9, 16 cores at 125W, and the Gold 6148, 20 cores at 150W. Platinum 8160 class sits in the same socket. Six DDR4 channels, up to 2666, 48 lanes of PCIe 3.0. 2nd Gen is Cascade Lake-SP on that same LGA3647 footprint: Silver 4214, Gold 6230 at 20 cores and 125W, Gold 6248 at 20 cores and 150W, Gold 6252 at 24 cores and 150W, Platinum 8260, and Platinum 8280 at 28 cores and 205W. Memory can step to 2933. PCIe stays at 3.0.

The R-suffix refresh is still 2nd Gen and still this socket. A Gold 6248R is 24 cores at 205W. A Gold 6258R is the high-core refresh, also 205W. They want a later BIOS than the original Cascade Lake launch image. A board last touched in 2018 will take the 6130 and halt on the 6248. The halt is during POST, before any installer. Tested, on our bench, means the chip posted in a compatible 14G board that already had a current BIOS and a current iDRAC9. Your R740 still needs that firmware. Update iDRAC first, then the BIOS, and apply the CPLD package when Dell's bundle for that service tag lists it. Pushing only the BIOS, with iDRAC left on the 2018 image, is how the update fails halfway and the new CPU still will not post.

Engineering samples are a coin flip even when the ILM closes. The lid marking on those is a Q-spec, not a production sSpec. Off-roadmap OEM steps that never appeared on Dell's matrix do the same thing: they drop in, and the board stops. We quote production parts. SR3B9 is a Gold 6130. If the photo of the IHS shows a QDF code, send it before you pay. Tray CPUs and Dell-branded CPUs of the same sSpec are the same silicon. The questions that matter are whether this BIOS lists that sSpec, and whether the heatsink can cool the wattage. A second-hand 6248 with a scraped corner of pads is scrap. Look at the pad field, not only the laser mark.

Buy the pair. Two sockets want the same model. A Gold 6130 beside a Gold 6148 shares LGA3647 and still fails the pair check on a 14G board. Match the sSpec when you can see it. Two lids that both read Gold 6248 can be different steppings, and a strict BIOS build will stop on that pair. A one-socket R740 is a valid build. It only trains the CPU1 DIMM slots. The twelve slots on CPU2 stay dark, and ordering twenty-four modules for that chassis wastes half the box.

Heatsinks and the 205W line

Dell's matrix for this chassis tops out at 205W, the Platinum 8280 and the Gold 6248R class. The standard heatsink that left the factory on a Silver 4114 is the wrong metal for that CPU. The 4114 is 85W. The 8280 is 205W. The air shroud and the heatsink are a pair. The shroud ducts the fan wall onto the sink. Run the high-wattage chip under the low sink, or run the chassis with the shroud left in the lid of the donor because a card was in the way, and the socket thermal-trips. iDRAC then logs a throttle or a shutdown that looks like a bad CPU. The CPU is doing what the cooler allowed.

Put the heatsink on the quote when the TDP is 150W or higher and the donor was a Silver build. A 125W Gold 6130 or Gold 6230 is usually fine on the standard sink already in the chassis. A 150W Gold 6148 or Gold 6248 is the middle of the range. If you do not know which sink is installed, a photo down the fan shroud is enough for us to tell the low sink from the high one. A CPU-only listing is a bare IHS in a clamshell. The sink is a second line. We pull processors from the CPU stock. Say the wattage you are moving to, and we will tell you if the sink has to move too.

GPU risers change the shroud again. The GPU duct is a different plastic part from the standard CPU shroud. Running neither, because the GPU kit arrived without the duct, cooks the CPUs and the mini PERC that sits under the same airflow. A 1600W or larger supply usually comes with that GPU build. The 495W module from the Silver chassis will seat in the bay and then fault once the accelerators and the second CPU come up.

DIMM order, speed bins, and the capacity cap

Memory is twenty-four DDR4 slots. Six channels a socket, two DIMMs a channel. Dell marks CPU1 as A1 through A12 and CPU2 as B1 through B12. Fill the white slot on every channel before the black one. Leaving the white slot empty and stuffing the black one is a common reason a good stick never appears in the inventory. Six DIMMs per socket, one per channel, is the balanced layout. Twelve per socket fills both slots. Eight per socket leaves channels empty. The board usually still posts. The interleave is lopsided, and you paid for bandwidth you are not getting.

1st Gen tops out at 2666. A Gold 6130 never had 2933. 2nd Gen can do 2933 at one DIMM per channel, on the SKUs whose memory controller is rated for it. A Silver 4114 or a Silver 4214 is capped lower, at 2400. The sticker on the module does not move a Silver cap. With both slots filled, ordinary 2Rx4 parts usually train at 2666 even on a Gold that can do 2933 at one DIMM per channel. A few 2nd Gen SKUs hold 2933 at two DIMMs per channel. If you bought 2933 modules to run at 2933, stay at six DIMMs per socket until you have checked that CPU. A 3200 module such as Samsung M393A4K40EB3-CWE, a 32GB 2Rx4 RDIMM, downclocks to whatever this CPU and this population allow. It does not make an R740 a 3200 machine.

DDR5 is keyed differently and will not seat. A DDR5 RDIMM from an R760, or an MRDIMM from a Xeon 6 box, belongs in that later chassis. Forcing the key bends pins. RDIMM and LRDIMM do not mix in this board either. One LRDIMM in a bank of RDIMMs and POST stops, or it trains part of the board and leaves the rest dark. Samsung marks the split in the prefix: M393 is a DDR4 RDIMM, M386 is a DDR4 LRDIMM. A 32GB stick we see beside the 3200 part is M393A4K40CB2-CTD, 2Rx4 at 2666. A 64GB 4Rx4 LRDIMM such as M386A8K40BM2-CTD means the whole server is LRDIMM. A 128GB module is usually 8Rx4, often a 3DS stack, and a chassis full of those drops another speed bin. Same part number across the box is the population that trains cleanly. The longer version of the mix rules is in the RDIMM and LRDIMM note. Match the label you already have, and buy from the memory list against that label.

The CPU suffix caps capacity even when every slot trains. A plain Gold 6248, no letter, addresses about 1TB per socket. The M parts, such as a Platinum 8280M, go to about 2TB. The L parts go higher still. Twelve 128GB LRDIMMs on one socket is 1.5TB. On a non-M Cascade Lake Gold the last half terabyte never becomes usable memory. iDRAC still lists every DIMM. The operating system lists the cap. Read both before you open a claim on sticks that passed in the tester. Skylake is tighter. A standard 1st Gen Platinum often stops at 768GB, and the M suffix on that generation is the higher bin. Read the model engraved on the IHS, including the letter, before you pay for the dense modules.

Optane Persistent Memory is a different population in the same slots. The 100-series modules, the NMA1 parts at 128GB, 256GB, and 512GB, need a 2nd Gen CPU. A Gold 6130 will not train them. They also will not pair with LRDIMM. Dell's table puts a DRAM RDIMM in the first slot of the channel and the persistent module in the second. Filling every slot with Optane, or dropping one module into a bank of ordinary 32GB sticks, fails training. The 200-series modules, the NMB1 parts, are the Ice Lake modules from an R750. They are the wrong spare for this chassis. A listing that says 128GB DDR4 and shows a tall heatsink is often one of these. Ask for the NMA1 or M386 line before you treat it as more RAM.

Two BIOS settings hide capacity after a good train. Memory Operating Mode set to Mirror cuts the usable size roughly in half. Single Rank Spare holds a rank back. Optimizer is the mode you want unless you meant to give up capacity. iDRAC still shows every DIMM at full size, which is why the OS number and the sticker number disagree. Check the mode before you reorder sticks you already own. A half-latched DIMM can also train at the wrong width and then throw corrected ECC that looks like a dying chip. Power the chassis off, reseat, and clear the log once. A climbing corrected-error count on one locator after that is a module to retire.

The H740P and the mini slot

The storage slot on the R740 planar takes a mini mono card. The four you will actually be offered are the HBA330, the H330, the H730P, and the H740P. The slot is the same family as the 13G R730. A 12G H710P mini from an R720 will not mate with it. The 15G front bay is a different opening again. An H755 does not belong in this slot, and an H740P mini does not belong in an R750. The longer map, from the H310 through the 16G cards, is the PERC generations note. For this chassis the choice is the four cards above.

HBA330 is pass-through. Each disk shows up with its own serial, which is what ZFS and TrueNAS want. H330 is RAID without cache and without RAID 6. One letter separates them. Ordering the H330 for a pool is the miss we see most often on 14G. Later firmware on an H330 can expose a non-RAID disk in some modes. That is still the RAID stack, and it is still the wrong card when the build was supposed to be an HBA. The H730P mini is the 2GB card from the 13G line, and it does seat in an R740. The H740P mini is the 14G high card: 8GB of flash-backed cache, RAID 6 included, 12Gb SAS. Buy the H740P when you want that cache on this backplane.

The 8GB does nothing useful in write-through. What preserves write-back across a power cut is a supercap on a cable, a different part from the lithium pack on an H710. An H710 battery will not plug into an H740P. A missing or failed supercap leaves RAID 6 in place and drops the virtual disk to write-through. Random writes on a parity volume get slow, and the disks still look healthy. perccli shows the battery line. Ask for that line if write-back is why you are paying for the 8GB. A swollen pack is scrap. It leaks onto the cache and takes the card with it. Forced write-back with a dead pack should be turned off before you trust the volume.

A full-height H740P adapter belongs in a riser, with a different cable path. The factory harness is dressed to the mini slot. It does not stretch to a riser because you changed form factor. The plug is mini-SAS HD, SFF-8643. The SFF-8087 leads in a 12G spares drawer will not latch. S140 is chipset RAID in the 14G chipset. It can mirror two SATA devices when the storage slot is empty. It is a weak place for a data volume. If iDRAC shows S140 and the front bays are SAS, you still need a real controller. We sell the card in the firmware it already has. We do not cross-flash an H740P or an H330 to IT mode. If the pool needs raw disks, order the HBA330 mini, or a 9300-8i already on IT firmware from the RAID and HBA list when the card is going into a riser. The mini has no standard bracket. The 9300-8i does not fit the storage slot.

The H840 is the external adapter of this era, 8GB of cache, for a 12Gb shelf. It does not light the front bays. BOSS-S1 is not a PERC either. Front NVMe bays are outside the SAS controller's job. A SAS backplane plus an NVMe U.2 drive in a caddy is a dark bay. Those bays need the NVMe backplane and the PCIe cables back to the CPU.

Backplanes, the xd, and NVMe

Read the backplane sticker before you assume one x8 card sees every slot. An 8-bay chassis is often one SFF-8643 harness into the mini slot. A 16-bay or 24-bay chassis may sit behind an expander on that one card, or it may be direct-attach and want two connectors. Some R740xd configs split the bays across the mini card and a second adapter. One H740P does not grow ports because the badge says 740. Factory cables reach the factory slot. They are the wrong length once you move the controller to a riser.

NVMe on 14G is CPU-direct. The H740P does not speak those lanes. The backplane has to be the NVMe one, and the slimline cables have to land on the board. A single-CPU R740 often lights only the bays owned by CPU1. The rest stay dark until the second processor is installed, even when the drives and the caddies are correct. Empty bays in a listing photo do not tell you which wiring you have. If you need the front of the chassis to take U.2, say so. We will not quote a SAS H740P into that job, and we will not quote an NVMe drive into a SAS-only backplane.

Sector size has to match the set you are joining. 512e and 4Kn do not belong in the same virtual disk. Match a replacement member to the survivors. A drive that still carries another controller's metadata sits foreign and refuses to join, or it offers an import you did not mean to accept. Disks for a new array should arrive wiped. Say so if the drive is a replacement member and has to stay untouched. SAS and SATA can share a backplane. Keep one virtual disk on one interface. Mixing them inside a single RAID 6 is how rebuilds get strange. Drives themselves are on the HDD and SSD lists. The caddy is a separate line, and it is the part the next section is about.

Caddies: DXD9H and X7K8W

The tray is the part people treat as generic. It is not. The 14G 2.5-inch tray is DXD9H, often printed with a leading zero as 0DXD9H. The 14G 3.5-inch tray is X7K8W. A 13G tray from an R730 slides into a 14G 2.5-inch bay and fails to latch. The LED board does not meet the backplane the way the 14G tray does. The drive may spin. iDRAC still marks the bay faulted or empty. Replacing the disk does not fix a latch that never caught. We see that return after the disk has already been reseated twice.

X7K8W will not enter a 2.5-inch bay. DXD9H will not fill a 3.5-inch bay. The 9W8C4 adapter puts a 2.5-inch drive in the 3.5-inch tray, and only in a 3.5-inch chassis. It is a second part. A loose drive with no tray is not a caddy. A black tray with the part number cropped is how 13G and 14G get mixed in one carton. The sticker on the side of a DXD9H says DXD9H. Ask for that corner if the title only says Dell 2.5 caddy.

15G trays from an R750 are a different latch and a different LED board. A DXD9H does not lock in an R750, and an R750 tray does not lock in an R740. 16G trays are another shell. If you are filling the R740 you already own, stay on DXD9H or X7K8W. The 2.5-inch tray is the hybrid shell Dell used so a SAS, SATA, or NVMe drive can sit in the same metal. The backplane still decides whether that drive enumerates. The caddy only gets the connector onto the backplane. Rear flex bays use the same 2.5-inch tray when the flex bay is a 2.5-inch cage. They do not take the 3.5-inch tray. Count the bays you are filling, including a mid bay on an xd, and order that many. Two spares of the right generation are reasonable. A spare from the previous generation is a part that almost fits.

Power, BOSS-S1, and the rNDC

Power supplies are 14G hot-plug modules: 495W, 750W, 1100W, 1600W, and the 2000W and 2400W units on dense and GPU builds. Match the pair. If the two wattages differ, the redundant capacity follows the smaller supply, which is a poor way to buy headroom. Two Gold 6248 processors and a full disk set want 1100W. The 495W module from a single Silver build is the wrong spare. It will seat. It will also fault or throttle when the second CPU and the cage come up. A 13G supply from an R730 does not latch in this shell. A 15G supply from an R750 does not either. The housings look related in a top-down photo. The latch and the edge connector do not. A barebone with one supply is a complete order only after you decide the second module. Chassis are on the barebones list. The wattage is a line we need before we pick the spare.

BOSS-S1 is a separate boot card. Two M.2 SATA modules, in a small PCIe board, for the operating system. It is not included with an H740P. It does not run the front bays, and the front bays do not become a boot mirror because a BOSS card is in the riser. The modules are SATA M.2. An NVMe M.2 stick from a laptop drawer is the wrong part for this carrier. BOSS-S2 is the 15G module, from an R750, and it does not fit this connector. People order "Dell BOSS" and receive the generation that matches the title's year. Name the chassis. S1 is the R740 part.

The network daughter card is an rNDC. It is the slot on the planar for the 1Gb or 10Gb board that ships with the system, an Intel X550 10GBASE-T card or a Broadcom 57416 SFP+ card in the common builds, or a 1Gb board when the original order was cheap. It is not OCP 3.0. OCP 3.0 shows up on the R750 and on 16G. An OCP card from those machines will not screw into an R740, and an rNDC will not screw into an OCP bay. A PCIe X710-DA2 in a riser is a normal add-on when you need SFP+ and the daughter slot is already full, or when the daughter card is the wrong media. Match the cage to the switch. SFP+ on the switch means a DA card and a DAC or an SR optic. An RJ45 daughter card does not take that optic. NICs are on the network cards list. A ConnectX-4 in a riser works as a PCIe device on this generation. It does not replace the rNDC, and it does not become a storage controller because both boards are small.

iDRAC9 Enterprise is a license tied to the service tag, not a different motherboard. A used pull often arrives on Express. The server still posts. Virtual console and virtual media are the features that are missing. Ask if you need them. We cannot invent a license that was never on the tag. The dedicated iDRAC port is on the back of the chassis whether the license is Enterprise or Express.

What the listing photo hides

A top-down shot of a heatsink, a DIMM, or a green PERC leaves out the lines that decide the order:

  • The ear. R740, R740xd, R750, R760, or an AMD cousin such as an R7425. The bezel is not the model.
  • The CPU sSpec and the wattage. SR3B9 is a known Gold 6130. A Q-spec is a question, not a spare. The sink is not in a CPU-only photo.
  • The DIMM label. M393 versus M386, the rank, and 2666 versus 2933 versus 3200. A tall 128GB stick may be Optane.
  • Mini mono versus a PCIe adapter, and H330 versus HBA330 versus H740P. The supercap is often outside the crop, on a cable.
  • The caddy sticker. DXD9H or X7K8W, not "Dell tray."
  • PSU wattage printed on the module, and whether you are looking at one supply or a matched pair.
  • BOSS-S1 versus BOSS-S2, and an rNDC versus an OCP 3.0 card from a newer Dell.
  • The backplane. SAS, expander, or NVMe. Bay count. R740 versus R740xd.

A tested note means the part posted in a compatible 14G board. It does not mean your BIOS is new enough for a 6248, and it does not mean the supercap is healthy. The service tag is seven characters on the ear tag. A photo of that tag, plus the iDRAC inventory if the machine still powers on, throws out most of the wrong stock before anyone ships it.

What to send us

Message the chassis on WhatsApp or Messenger before you pay for a Gold 6330, an H755, or a 13G tray. A photo of the ear and of the part you are replacing is enough when you do not have the service tag in front of you. We match the CPU, the DIMMs, the controller, and the tray, and we ship from Hong Kong.

  • Service tag, or a clear photo of the ear: R740 or R740xd, and not an R750.
  • CPU model you have, and the model you want, including any M or L suffix. One socket or two.
  • A label photo of a DIMM already in the box, and how many slots you intend to fill.
  • RAID or pass-through. Say ZFS or TrueNAS if the disks have to stay raw. Say if the H740P supercap has to be in the box.
  • Bay count and drive size: 2.5-inch DXD9H or 3.5-inch X7K8W, and whether any bay is NVMe.
  • PSU wattage installed today, and whether you are adding the second CPU, a full cage, or a GPU.
  • BOSS-S1 if the OS has to move off the front bays, and the NIC media if the rNDC is part of the order.

A Gold 6248 with a current BIOS, a matched heatsink, six or twelve RDIMMs per socket, an H740P or an HBA330 in the mini slot, and DXD9H trays is a coherent R740 order. A Gold 6330, an H755, and an R750 caddy are a coherent R750 order. Send the ear and we will quote the set that seats in the chassis you have.

All guidesFAQContact