Guides

Dell PERC generations and chassis fit

H310, H710, H730P, H740P, and H755 do not share one mini connector from 12G through 15G. The chassis ear picks the card, the cable, and whether you needed an HBA330 or an HBA355.

The sticker says PERC. The chassis decides which board that word is allowed to mean. A mini card out of a 12G R720, a mini card out of a 14G R740, and a front controller out of a 15G R750 can all be photographed as a green board under a heatsink. The connector on the bottom, or the carrier around the board, is the part that seats. We match used controllers in Hong Kong to the server you already own. The model on the ear comes before the price.

From 12G through 15G there is no single mini card that fits every PowerEdge. The 12G mini mono does not mate with a 13G or 14G storage slot. 13G and 14G share that slot, so an H730P mini can move from an R730 to an R740, while an H740P mini is still the 14G part you buy for the R740. 15G drops the mini mono and puts the controller in a front bay. A card that looks right in a top-down photo is the usual reason a rebuild stops on the bench.

12G mini: H310, H710, H710P

12G is the R620, R720, R720xd, and T620. The CPUs are Xeon E5-2600 and E5-2600 v2, on LGA2011, with DDR3. The planar has a dedicated storage slot for a mini mono card, and the SAS link on that generation is 6Gb. The three internal controllers you will actually be offered are the H310, the H710, and the H710P.

The H310 has no cache and no battery. RAID 0, 1, 5, 10, and 50. RAID 6 is absent. The silicon is an SAS2008-class MegaRAID, the same generation as an old 9240, and the disks show up as virtual drives. That is a poor fit for ZFS. It is also the card people ask us to cross-flash to IT firmware so it behaves like a 9211. Flashing stays off the order. The card ships as a RAID PERC. If the pool needs raw disks, buy an HBA that is already an HBA.

The H710 adds 512MB of DRAM cache and a lithium battery pack. RAID 6 and RAID 60 are available. The H710P is the same controller with 1GB of cache. Both of them want a healthy pack. When the pack fails a learn cycle, or when someone pulled the card and left the battery screwed to the chassis wall, the virtual disk drops to write-through. The volume still comes online. Random writes on RAID 5 or RAID 6 get slow, and perccli shows the battery as a replace item. A previous owner may have forced write-back with no pack. Turn that off. A power cut in the middle of a parity stripe corrupts a volume that otherwise looked fine.

The mini mono seats in the 12G storage slot. It does not seat in an R630 or an R730. The adapter is a normal PCIe card, and the bracket already on it is either full height or low profile. A 1U R620 cares which one you were sent. An H810 is the external cousin, with 1GB of cache and SFF-8088 connectors, for an MD1200 shelf. It does not run the internal bays of an R720. Internal cables on this generation are SFF-8087. A later SFF-8643 lead, the mini-SAS HD plug used from 13G onward, will not latch into an H710.

Blades are a third shape. An H710 Mini Blade from an M620 uses the blade mezzanine connector. In a parts photo it is another small Dell RAID board. It does not drop into an R720 storage slot, and an R720 mini does not go into the blade. The label has to say mono or blade. 4Kn disks are a bad match for this whole generation. If the replacement drive is 4Kn, this is the wrong PERC family to join it to. Sector size on the surviving members matters more than the newest listing in the search results.

13G: H330, H730, H730P, HBA330

13G is the R630, R730, R730xd, and T630. The CPUs are Xeon E5-2600 v3 and v4, on LGA2011-3, with DDR4. SAS steps up to 12Gb, and the storage-slot connector changes with it. A 12G H710P mini will not mate with that slot. People still order it because the photo is a mini card and the title says PERC. It arrives, it does not seat, and the R730 is still waiting on a controller.

The H330 is the entry RAID card. No cache, no battery, no RAID 6. RAID 0, 1, 5, 10, and 50. The chip is an SAS3008 in a RAID personality, the light MegaRAID class. One letter separates it from the HBA330, and that letter is the job. The HBA330 is pass-through. Each disk shows up with its own serial, which is what ZFS, TrueNAS, and Storage Spaces want. The H330 still owns the disks as virtual drives. Ordering an H330 for a pool is the miss we see most often on 13G. Later firmware on an H330 can expose a non-RAID disk in some modes. That is still the RAID stack, and it is still the wrong card when the build was supposed to be an HBA.

The H730 has 1GB of flash-backed cache. The H730P has 2GB. Most R730s left the factory with an H730P mini in the storage slot. The cache sits on the card. What preserves it across a power cut is a separate pack, and that pack is a different part from the lithium brick on an H710. Different connector. A dead or missing pack forces write-through. RAID 6 stays available. The writes stop being acknowledged out of cache. The 2GB on an H730P does nothing useful while the policy is write-through.

An H730P adapter is a PCIe card for a riser, or for a tower where the mini slot is already full. The R730 backplane harness is dressed to the storage slot. Changing form factor means new SFF-8643 cables, the right length, and a free x8 electrical slot. An x4 slot will run the card and then choke a cage of SSDs. The H830 is the external 13G card, 2GB of cache, SFF-8644 outside, for an MD1400. It does not replace the internal mini. A 12G adapter can physically occupy a PCIe slot in an R730. The cables are the wrong plug, the link is 6Gb, and iDRAC only half-manages a card the chassis was never built around. We quote the 13G part.

The HBA330 mini uses Dell HBA firmware on that same SAS3008 generation as a 9300-8i. It is a different mechanical part. The mini has no standard bracket. It fits the Dell storage slot. A Supermicro or a generic tower wants the HBA330 adapter, or a normal 9300-8i already on IT firmware. We sell each of those as it is. We do not flash one into the other.

14G shares the mini slot and adds the H740P

14G is the R640, R740, R740xd, and T640. The socket is LGA3647. 1st Gen Xeon Scalable, Skylake-SP, is the Gold 6130 and Gold 6148 class. 2nd Gen, Cascade Lake-SP, is the Gold 6230 and Gold 6248 class. Memory is still DDR4. The storage slot on these boards is the same mini mono family as 13G. Dell lists the H330, the H730P, the HBA330, and the H740P for an R740.

An H730P mini pulled from an R730 does seat in an R740. A 12G H710P mini still does not. The H740P is the high card 14G shipped with: 8GB of flash-backed cache, RAID 6 included, 12Gb SAS. Buy that for an R740 when you want the large cache. Leave the H740P out of the plan for an R730. The connector generation may look related on a diagram. The 13G planar and its firmware support list are the H730 family. Order the card that chassis lists.

Passthrough on 14G is still the HBA330 mini. Same Dell HBA firmware as the R730 part, same cables, same limit: the mini bracket does not screw into a third-party riser. If the host is an R740 and the pool is ZFS, the HBA330 mini matches the harness already in the lid. If the host is a white box, take a PCIe HBA off the RAID and HBA list. Link speed on the 14G SAS backplane stays 12Gb. Cables stay SFF-8643. The SFF-8087 leads in a 12G spares drawer do not plug into an H740P or an H730P.

The H840 is the external adapter of this era, with 8GB of cache, for a 12Gb shelf. It is a PCIe card. It does not occupy the mini slot, and it does not light the front bays. BOSS-S1 is the other board people confuse with a PERC. It is a small boot module for two M.2 SATA devices. It is a separate line on the order from an H740P. Front NVMe bays are also outside the SAS PERC's job on 14G. A SAS backplane plus an NVMe U.2 drive in a caddy is a dark bay. Those bays need the NVMe backplane and the PCIe cables back to the CPU.

An R740 and an R740xd are different backplanes. Eight 3.5-inch or sixteen 2.5-inch is the plain R740. Twenty-four 2.5-inch, or a mid-bay, is the xd. Some xd configs split the bays across the mini card and a second adapter. One H740P does not grow ports because the chassis is taller. Read the backplane sticker before you assume a single x8 card sees every slot. The M640 blade uses a blade mezzanine, a different FRU from the R740 mini, even though both machines are 14G.

Chipset RAID is a further trap on this generation. S140 is software RAID in the 14G chipset. It can mirror two SATA devices when the storage slot is empty. It is a weak place for a data volume, and it is not a stand-in for an H740P or an HBA330. If iDRAC shows S140 and the front bays are SAS, you still need a real controller.

15G moves the card to the front

15G is the R650, R750, and the xs and tower variants around them. The CPU is 3rd Gen Xeon Scalable, Ice Lake, on LGA4189. Memory is still DDR4, up to 3200, and the lanes are PCIe 4.0. A Gold 6330 belongs here. It does not belong in the R740 you pulled the last PERC from. The old mini mono slot is gone. The controller sits in a front bay, behind the drive cage, on a carrier that does not exist in an R740. An H740P mini does not belong in an R750. An H730P mini does not either.

RAID on a 15G SAS backplane is the H755, usually with 8GB of cache. Passthrough is the HBA355. Read the label twice. The H355 and the HBA355 are different cards. The H355 is the entry RAID part, no cache, the right size of card for a mirror and the wrong card when every disk has to be handed to the OS. The HBA355i is the internal pass-through card. The HBA355e is the external one, for a shelf, and it does not run the front bays by itself.

The H755N is NVMe RAID, for a backplane wired as NVMe. It is a different board from the SAS H755. An H755N in front of a SAS expander leaves the spindles dark. A SAS H755 in front of a pure NVMe backplane leaves the U.2 bays dark. The backplane label settles it. Cable kits for the front carrier are short and specific to that bay. A loose H755 board with no 15G carrier, and no leads that reach that bay, is a card you cannot install in the chassis you have. The H745 is a PCIe adapter from the same period. It belongs in a riser. It does not drop into the front carrier.

S150 on 15G is the chipset RAID feature, the same idea as S140 on 14G. An empty front bay in the parts list means the original build may have been S150 plus BOSS, with no hardware PERC at all. Budget for the carrier and the cables, not only the chip.

AMD Dell servers of these years are their own chassis. An R7525 is EPYC Milan, socket SP3, DDR4. An R7625 is the 16G AMD chassis: Genoa, and Bergamo on the density SKUs, socket SP5, DDR5. Turin, EPYC 9005, uses SP5 as well and belongs in a later PowerEdge. The front-controller idea is similar across those lids. The carrier and the cable lengths are not a kit you harvest from an Intel R750 and drop into the AMD chassis. Send the model off the ear. OCP 3.0 on these machines is the NIC slot. A PERC does not occupy it, and an OCP network card does not become a RAID controller because both parts are small and Dell-branded.

16G, 5th Gen, and the next chassis

16G is the R660 and R760. 4th Gen Xeon Scalable, Sapphire Rapids, and 5th Gen, Emerald Rapids, share LGA4677 and DDR5. A 4th Gen Gold 6430 and a 5th Gen part such as a Gold 6526Y are both 16G CPUs. The BIOS has to list the generation you install. Sharing a socket with Sapphire Rapids does not mean a 2023 BIOS will take Emerald Rapids. The PERC does not turn a 15G board into a 16G board, and a 16G front bay is no place for a 13G mini.

The tri-mode controller on 16G is the H965i. SAS, SATA, and NVMe, with 8GB of cache, for backplanes that are actually wired tri-mode. The matching HBA is the HBA465i. The external HBA is the HBA465e. Dell still offers an H755 on some 16G SAS-only builds. That does not make every H755 pulled from a 15G a drop-in FRU for an R760. The carrier, the cable, and the backplane part number have to match the service tag. Order the H965i when the bays are NVMe or mixed. A SAS H755 does not grow tri-mode because the chassis is newer.

Xeon 6, the generation after 5th Gen Scalable, sits in a later PowerEdge. Treat that as another chassis. An H755 or an H965i is a guess until the ear says the model. We match the controller to that model. OCP 3.0 is still the network slot on 16G. Storage stays on the front controller bay. Listings that say OCP RAID are usually a mezzanine from another vendor, or a guess from the seller.

Memory generation and the PERC generation travel together only because they travel with the chassis. DDR4 from an R740 does not move to an R760, and the H740P does not move with it either. DDR5 on 16G, including the higher bins 5th Gen can train, does not change which RAID card the backplane wants. If you are rebuilding the whole server, quote the CPU, the DIMMs, and the controller against one service tag. Mixing a 14G storage slot card into a 16G front bay fails before the memory even trains.

Batteries, supercaps, and write-through

Cache and the word PERC are separate line items. On an H710, H710P, H730, H730P, H740P, H755, or H965i, ask whether the pack is in the box. The H310, H330, H355, HBA330, HBA355, and HBA465i have nothing to protect. A battery added to that order has nowhere to plug in.

On the H710 and H710P the cache is DRAM and the protection is a lithium pack. Those packs are old. Plenty of them fail the next learn cycle after years in a drawer. perccli reports the battery, and the virtual disk sits in WT, write-through. While a learn is running, write-back can stay off for hours. Benchmark the next day. A swollen pack is scrap. It leaks onto the cache and takes the card with it.

From the H730 onward the protection is flash-backed. A supercap holds enough energy to destage DRAM into NAND when the server loses power. That pack uses a different connector from the H710 brick. An H710 battery does not plug into an H730, an H740P, or an H755. A missing supercap leaves RAID 6 in place on these Dell cards. It removes write-back. The 8GB on an H740P or an H755 does not change the policy. Write-through means the controller waits for the disks before it acknowledges the write. A database notices. RAID 10 notices less, and it still notices.

The pack is easy to crop out of a listing photo. On many chassis it is a small module on a cable beside the mini card, or on the side wall, outside the frame. A tested note means the card posted and saw disks. It does not mean the pack is healthy. Ask for a perccli or iDRAC line that shows the battery or supercap healthy, and the logical drive in write-back if write-back is why you are paying for the cache. Forced write-back with a failed pack should be turned off before you trust the volume.

Cables, bay count, and 4Kn

The backplane decides how many ports you need. An 8-bay chassis is often one SFF-8643 harness into the mini slot or the front carrier. A 16-bay or 24-bay chassis may sit behind an expander on one x8 card, or it may be direct-attach and want two connectors. Ordering a single H740P because the title said R740, then finding an xd harness that does not reach, is a normal ticket. Factory cables reach the factory slot. They do not grow a path to a riser when you change from mini to adapter.

Sector size has to match the set you are joining. 512e and 4Kn do not belong in the same virtual disk. The H710 era is a bad place for 4Kn disks. The H730 and newer cards generally handle them. If this drive replaces a failed member, match the survivors. A 4Kn nearline disk that works on a 9300-8i can still be rejected by an H710 in the only server you have.

Moving a virtual disk from an H710 to an H740P and hoping for a clean foreign import is a bad migration plan. Metadata and cache generations moved. If the volume has to live, stay in the same PERC family, or back it up and rebuild on the new card. Used disks create the opposite problem. A drive that still carries another controller's metadata sits foreign and refuses to join, or it offers an import you did not mean to accept. Disks for a new array should arrive wiped. Say so if the drive is a replacement member and has to stay untouched.

SAS and SATA can share a backplane. SATA is single-ported, so a dual-domain shelf loses the second path. Mixing SAS and SATA inside one virtual disk is how rebuilds get strange. Keep the virtual disk on one interface. Large nearline disks and some SSDs also want a PERC firmware that actually lists them. Updating that firmware is a Dell package run from iDRAC on your chassis. We do not cross-flash a generic MegaRAID image onto a Dell card to get there, and we do not promise a firmware bump as part of a pull.

Airflow is dull until the card vanishes after a week. Mini cards and front controllers sit under the shroud and depend on it. An R730 or R740 run with the shroud out, or with a GPU parked against the storage slot, cooks an H730P or an H740P. The heatsink is small. The chip still wants the duct that shipped with the chassis.

Pass-through cards, and flashing stays off the order

ZFS and Storage Spaces want the disk. A virtual drive hides the serial, complicates SMART, and makes a single-disk replace harder than it should be. On 13G and 14G the pass-through card is an HBA330. On 15G it is an HBA355. On 16G it is an HBA465i when the backplane is tri-mode, or the HBA Dell lists for that SAS backplane when it is SAS only. A RAID PERC left on RAID firmware still owns the disks.

We sell the card in the firmware it already has. Flashing an H310, an H330, an H730, an H740P, or an H755 over to IT mode is not part of the sale. Putting a generic MegaRAID image on a Dell PERC is the same answer. Dell firmware is what iDRAC and the lifecycle controller expect. A cross-flash can boot once on a bench and then fail the next update, or drop the identity the chassis checks. Order the behavior you need.

A generic LSI 9300-8i on IT firmware is the right buy when the chassis has no Dell storage slot. Two SFF-8643 connectors, SAS3008, PCIe 3.0 x8. Same generation as the HBA330, different metal. The 9300 does not fit a mini mono slot. The HBA330 mini does not fit a standard bracket. Pick one. Both sit on the RAID and HBA page. The listing has to say HBA or IT before you compare that price to an H730P. A 9361-8i is MegaRAID with cache. It does not become an HBA330 because it uses the same SAS plug.

What the listing photo hides

The heatsink looks the same across a decade of pulls. A top-down shot of the chip leaves out the lines that decide the order:

  • Mini mono, mini blade, PCIe adapter, or a 15G and 16G front carrier. The mounting is the compatibility.
  • The full model. H330 and HBA330. H355 and HBA355. H755 and H755N. H710 and H710P. H730 and H730P.
  • The battery or supercap, often a separate FRU on a cable outside the frame.
  • The bracket. Low profile versus full height matters in a 1U. A mini card has no bracket at all.
  • Cables. The chassis harness reaches the factory slot.
  • Cache size. 512MB, 1GB, 2GB, and 8GB are different cards.
  • Which chassis it was pulled from. An R720 mini, an R740 mini, and an R750 front card are three purchases.

A tested note means the card posted and saw disks in a compatible chassis. It does not mean the pack is new, and it does not mean the card will seat in the generation you left unnamed. The ear is the filter. R720, R730, R740, R750, R760. That token throws out most of the wrong stock before anyone ships it.

What to send us

Message the chassis on WhatsApp or Messenger before you pay for a mini card from the wrong decade. A photo of the existing controller label and the backplane sticker is enough when you do not have the service tag. We match the card to that chassis and ship from Hong Kong.

  • Model off the ear: R720, R730, R740, R750, R760, or the AMD equivalent such as an R7525.
  • Mini mono, PCIe adapter, or front carrier.
  • RAID or pass-through. Say ZFS or TrueNAS if the disks have to stay raw.
  • Whether the battery or supercap has to be in the box.
  • Bay count, and SAS versus NVMe, if the cables are moving too.
  • The perccli battery line, if the card you have is already stuck in write-through.

A pack for an H710 does not fit an H730P, and an H740P mini does not fill an R750 front bay. Send the ear and the job, RAID or HBA, and we will quote the board that actually seats.

All guidesFAQContact