Guides
Buying a used 10GbE NIC
X710-DA2 is SFP+. X710-T2L and X550-T2 are RJ45. A Dell rNDC or OCP 3.0 card fills a different slot, and a ConnectX-4 Lx on a 10G switch links at 10G.
A used 10GbE NIC is three checks, in this order. The media on the switch port, the slot in the chassis, and the vendor string in the optic. Get those right and an X710-DA2 that has been running since 2018 is a boring, correct card. Get one of them wrong and the same card looks dead on the bench. The chip is rarely the part that failed.
In late 2026 the access port in a new rack is often SFP28 at 25G, or an OCP 3.0 slot on a 16G Dell, an HPE Gen11, or an EPYC Genoa or Turin board. A lot of switches already on the floor are still SFP+ or 10GBASE-T. Buy for the switch you have. A faster card in front of a 10G port links at 10G, and that is the link you paid the switch for.
X710-DA2 versus the T cards
The X710-DA2 is the dual SFP+ pull we see most. Intel XL710 silicon, PCIe 3.0 x8, driver i40e on Linux and on TrueNAS SCALE. Two empty cages. You add a DAC or an optic. The X710-DA4 is the quad-port version, a longer card, same family. Four 10G ports want the x8 the card was built for. In a narrower slot the ports still link, then they share the bus and a storage copy looks like a bad NIC.
The T cards are RJ45. X710-T2L is the dual 10GBASE-T part to ask for when the plant is copper. It is the lower-power refresh, and it also speaks 2.5G and 5G, which matters once the switch is a multi-gig port rather than a pure 10G blade. X710-T4 is the quad RJ45 card. It works. It also runs hot, and a 1U with a quiet fan curve will cook it. The later X710-T4L is the cooler quad copper part when you actually need four RJ45 ports. A title that says Intel X710 10GbE covers the DA2, the DA4, the T2L, and the T4. The cages in the photo are the filter. Empty SFP+ slots mean a DA card. RJ45 jacks mean a T card. There is no adapter that turns one into the other.
A 10GBASE-T module shoved into an SFP+ cage is the workaround people try when the switch is copper and the card on the shelf is a DA2. That module is a small PHY in a metal shell. It runs hot, the reach is short, often 30 meters on Cat6a, and a lot of X710 firmware rejects it as an unsupported transceiver. The port stays down. Plan on a T-series card if both ends of the run are RJ45. Keep the DA2 for DAC and fiber.
X520, X540, and X550
The X520-DA2 is the previous dual SFP+ card. The chip is the 82599, the bus is PCIe 2.0 x8, and the Linux driver is ixgbe. It is still a correct 10GbE NIC for Linux, Proxmox, TrueNAS, and Windows Server. It does not become an X710 because you seated it in a Gen4 or Gen5 slot. The link stays PCIe 2.0. An X520-SR2 is the same card with short-range optics already in the cages. Read the suffix. DA means empty cages. SR means the optics are part of the listing, and those optics may be coded for whoever owned the server, not for the switch you have now.
The X520 is looser about optic EEPROMs than the X710. A generic 10GBASE-SR that follows the SFP MSA usually links. That forgiveness is why these cards stayed in labs for a decade. It is also why an X520 is a bad guess for a new ESXi 8 host. ESXi 8 dropped native support for many 82599 device IDs. The box boots, the PCI device is visible, and no vmnic appears. On ESXi 8, buy an X710 unless that exact PCI ID is already proven on your image. On Linux the ixgbe driver is still in the kernel. Keep the X520 there.
The X540-T2 is the older dual RJ45 card, also PCIe 2.0 x8, also ixgbe. There is no SFP cage. It links at 10G or at 1G. It does not speak 2.5G or 5G. Hang it off a modern multi-gig switch port and it falls back to 1G, which looks like a cable fault and is actually the PHY. The heatsink is large because the card pulls more power than people expect in a packed 1U. It still has a job when the switch is genuine 10GBASE-T and the host is Linux. Treat ESXi 8 the same way as the X520: do not assume a vmnic until that PCI ID is on your image. The single-port X540-T1 is the same PHY with one jack.
The X550-T2 is the later copper card and the one we would rather ship for a new RJ45 install. PCIe 3.0, ixgbe, lower draw than the X540-T2, and NBASE-T on the usual firmware so 2.5G and 5G ports come up at those speeds instead of dropping to 1G. The retail X550-T2 is a x4 card, which is enough bus for two 10G copper ports. Current ESXi still has an inbox driver for it, which is why it is the copper default when the hypervisor is VMware and the switch has RJ45. An X550 does not take an SFP. Copper is the whole product.
Match the switch port, then the cable
SFP+ on the switch means a DA card, then either a DAC or a pair of optics. Inside one rack, a passive DAC is the right cable. One meter or three meters. Five meters is where picky switch ports start refusing a passive lead. Seven meters wants an active DAC or fiber. A Cisco-coded 3m passive lead is the SFP-H10GB-CU3M. An Intel-coded 3m lead is the XDACBL3M. They are both twinax. The EEPROM is the difference, and the end that enforces the code is the end that stays dark.
RJ45 on the switch means a T card and a copper patch. 10GBASE-T on Cat6a is the 100 meter spec. Cat6 is shorter, often quoted at 55 meters. In a rack, three meters of either will link. Old Cat5e is why a good X550-T2 negotiates 1G and gets blamed for it. Replace the patch before you replace the NIC. A switch port hard-set to 1000 will also stay at 1G no matter which card you install. Check the port config when the PHY is capable of 10G and the link light says otherwise.
Fiber is the long run. 10GBASE-SR is 850 nm on multimode, OM3 or OM4. 10GBASE-LR is 1310 nm on singlemode, OS2, out to 10 km. Both ends of the link have to be the same optic type. An SR module on a singlemode patch stays dark. A BiDi pair only works as a matched pair, opposite wavelengths. The Intel SR module that belongs in a retail X710 is the E10GSFPSR. The Cisco-coded SR module is the SFP-10G-SR. Same laser class, different EEPROM. Buy the code for the port it is about to enter, not a matched pair coded for the switch and then split between the switch and the server.
Optic coding on the NIC and on the switch
The module EEPROM carries a vendor name. Switches enforce it. Older Dell FTOS boxes sometimes still have a command to allow an unsupported transceiver. A lot of OS10 switches do not. An S4148 or S5248 leaves a generic SFP dark and logs the module as unsupported. Cisco Nexus is strict. Aruba CX is strict. HPE Comware on older FlexFabric gear was looser. The code you buy is the switch's code when the module sits in the switch.
NICs are looser than switches, and they are not all equally loose. An X520 will usually link a generic SR optic that follows the MSA. An X710 checks the vendor string harder. A module coded only as Cisco, including a used SFP-10G-SR, is often rejected. The kernel log says unsupported SFP, and the port stays down. A module whose EEPROM says Intel, such as an E10GSFPSR or a compatible coded that way, is the one that links in a retail X710 on Intel firmware. The words 10G SFP+ on the label are not the code. If the listing does not name the coded vendor, ask before you count on it for a storage VLAN.
Dell firmware changes the check again. A Dell X710, including the rNDC modules from 14G, can insist on Dell's list. Intel coding is not automatically Dell coding. That same Dell-firmware card can also refuse to link in a non-Dell board, because the option ROM wants a Dell subsystem path. If the chassis is a Supermicro or a white box, ask for a retail X710-DA2 on Intel firmware. If the chassis is the R740 the card was pulled from, the Dell firmware is the correct firmware. We do not cross-flash Dell NVM to a retail Intel image, and we do not recode optics as part of the sale. A bad flash is a brick. Order the card whose firmware already matches the board, and order the optic whose EEPROM already matches that card or that switch.
DAC cables fail the same check and fail it more often, because they get treated as plain wire. A passive SFP+ DAC between two Intel cards is a normal used buy at one or two meters. That same generic DAC into a Dell OS10 or a Cisco switch often never enables the port. Buy the DAC coded for the switch. Keep it short. Fiber between buildings is two optics plus a patch, each optic coded for its own host.
Dell NDC, rNDC, and OCP 3.0
The slot in the chassis rejects more orders than the chipset does. A standard X710-DA2 is a PCIe card. It goes in a riser. It does not fill a daughter-card bay, and a low-profile bracket does not change that. The gold fingers and the latch are different parts.
12G Dell, the R620 and R720, uses a network daughter card in a proprietary NDC slot. The usual pulls are a Broadcom 57810 dual 10G, or an Intel combination of 10G and 1G on the same mezzanine. 13G, the R630 and R730, uses an NDC as well, and the 12G card does not fit the 13G connector. They look related in a photo of the rear panel. The spare-part numbers are not interchangeable. A PCIe X710-DA2 still fits a free riser slot in either generation, full height or low profile to match the chassis.
14G, the R640 and R740, moves to an rNDC. Different opening, different connector. An Intel X710 rNDC is a common pull, dual SFP+ or dual 10GBASE-T depending on the FRU. Broadcom 57412 is the SFP+ rNDC we see beside it. Broadcom 57416 is the 10GBASE-T rNDC. A 13G NDC does not mount in an R740. An rNDC does not mount in a standard PCIe riser. In the original 14G chassis, a 57416 on matching firmware is a fair card. Moved to a generic host, bnxtnet can load and pass nothing useful. For a white box, take the retail Intel card.
15G, the R650 and R750, drops the rNDC and uses OCP 3.0. 16G, the R660 and R760, 4th and 5th Gen Xeon Scalable, keeps OCP 3.0. An rNDC from an R740 does not fit either machine. An OCP 3.0 NIC is a small card with a pull tab and gold fingers along the bottom edge. It screws to a carrier. It has no PCIe bracket. A top-down photo of the chip and the cages hides that edge, which is how an OCP card gets sold as a standard X710-DA2. HPE Gen9 and Gen10 use FlexibleLOM for the same job. A 560SFP+ or a 562FLR-SFP+ lives in that ProLiant bay and does not fit a Dell NDC. Gen11 moves to OCP 3.0. The FlexibleLOM card stays in the Gen10.
OCP 2.0 is an earlier mezzanine, still in some pulls, and it does not fit an OCP 3.0 slot. The screws and the connector both differ. Supermicro boards from the H12, H13, and H14 generations often have an OCP 3.0 slot beside ordinary PCIe. A Dell rNDC does not fill it. A retail X710-DA2 fills a PCIe slot on that board and leaves the OCP bay empty, which is a valid build. Xeon 6 platforms and EPYC Turin boards follow the same split: PCIe for the standard card, OCP 3.0 only when you ordered an OCP NIC. Milan on SP3 is the same idea on PCIe 4. The 10G card still runs at its own bus generation.
ConnectX-4 Lx links at 10G
The Mellanox card in the same used bins is the ConnectX-4 Lx. MCX4121A-ACAT is the dual SFP28 part, 10/25GbE, PCIe 3.0 x8, driver mlx5. The cages take an SFP+ module or a 10G DAC, and the link comes up at 10G. ethtool showing 10000 Mb/s is the card doing what the switch port allows. It is not a failed 25G port. A 25G DAC or an SFP28 SR optic into an SFP+ switch usually stays down. Buy the 10G cable when the switch is 10G. Buy the 25G cable when the switch is SFP28 and you want the higher rate.
That fallback is why the MCX4121A-ACAT is a sensible used buy in a rack that is mid-move from 10G to 25G. It lives on the old switch today and on the new switch later. If the switch is SFP+ and it is staying that way, a 25G card is optional. The link is 10G either way. The MCX4121A-XCAT has the same dual SFP28 cages and a hard cap at 10GbE. It links at 1G or 10G. It does not train at 25G in an SFP28 switch. Read the last four letters. ACAT can do 25G. XCAT stays at 10G. The single-port pair is MCX4111A-ACAT and MCX4111A-XCAT.
Intel's parallel card is the XXV710-DA2, dual SFP28, same 10G fallback with an SFP+ optic or a 10G DAC, driver i40e. A straight QSFP28 cable does not belong in either of these cages. Breakout from a 100G switch port is a switch setting plus a fanout cable, and the NIC end is still SFP28 or SFP+.
ConnectX-3 is the previous generation and a different driver, mlx4. A dual SFP+ ConnectX-3 can still link at 10G on Linux. It is a weak choice for a new ESXi host, and MLNX_OFED 5.x dropped it. Do not buy one because the price is lower and the bracket looks the same. ConnectX-5 25G, the MCX512A-ACAT, is the newer mlx5 card. It also takes a 10G module and links at 10G. Buy it when you want 25G headroom, not because a listing said Mellanox 10GbE and the photo was cropped.
OEM ConnectX cards keep an OEM PSID. A Dell or HPE firmware image is the right image in that vendor's slot, and a generic Mellanox image flashed over it can wipe the identity the server expects. We do not cross-flash PSID as part of the sale. The HHHL MCX4121A-ACAT on Mellanox firmware is the card that moves between a Dell riser, a Supermicro slot, and a white box. A mezzanine with the same chip is a different piece of metal.
Slot width, heat, and the bracket
One 10GbE port is a modest amount of bus. Dual 10G on an X520 or an X540 wants the PCIe 2.0 x8 those cards were built for, because a 2.0 x4 link is tight for two full-rate ports. An X710-DA2 on PCIe 3.0 is comfortable at x8 and usually fine at x4 for two ports. An X710-DA4 in an x4 slot is the one that contends. A Gen5 riser in an R760 or on an EPYC Turin board does not add lanes the card cannot train. The card's own generation is the ceiling. That is enough for 10GbE. You do not need an E810 unless the port is actually 25G or 100G. An E810-XXVDA2 is a 25G card on the ice driver, a different buy from a used X710.
Heat follows the PHY. An SFP+ DAC is the cool, low-power path. An SR optic is next. 10GBASE-T is the heater. The X540-T2 and the X710-T4 need the fan wall moving air across the heatsink. In a 1U next to a high-watt CPU they are the cards that thermal-throttle or drop a port in summer. The X550-T2 and the X710-T2L are the copper cards we would put in that chassis. A tower with no airflow over the PCIe slots is a bad home for any of the T cards.
Bracket height is a 1U problem. An R440, R640, or R650 riser wants the low-profile bracket. Used pulls often have the full-height bracket screwed on, and the low-profile one is missing from the bag. Ask. An rNDC and an OCP 3.0 card have no interchangeable PCIe bracket at all. Ordering a short bracket does not turn them into a standard card.
Drivers, ESXi, and firmware we leave alone
On current Linux, Proxmox, and TrueNAS SCALE, i40e drives the X710 and the XXV710, ixgbe drives the X520, the X540, and the X550, and mlx5 drives the ConnectX-4 Lx. Those drivers are in the kernel. You do not need a vendor ISO for a plain Ethernet link. Install a vendor stack when you need a feature the inbox driver does not expose, and match it to the kernel you actually boot.
ESXi is pickier. For a 10GbE order: X710-DA2 or X710-DA4 for SFP+ on ESXi 7 and 8, X550-T2 for copper, and an X520 only after that 82599 ID has already come up as a vmnic on your build. A Broadcom 57810 daughter card from a 12G or 13G Dell is a poor fit for ESXi 8. A listing that says Dell 10Gb dual-port is often that 57810, not an X710. Ask for the part number on the sticker.
The other cheap surprise is the I350-T4. It is an Intel quad-port server NIC, and it is 1GbE. So is the I340. Listings that say Intel quad port and show four RJ45 jacks are often these cards. The X710-T4 and the X540-T2 are the 10G copper names. If the model string is I350, you ordered gigabit.
We sell the NIC with the firmware it already has. We do not strip a Dell or HPE lock, we do not cross-flash an rNDC to retail Intel NVM, and we do not recode the optics in the bag. Firmware identity sits outside the usual swap-it-if-it-fails conversation, because a half-written NVM does not enumerate. Tell us the chassis and we will pick the card that already matches it.
What the listing photo hides
A top-down photo of a heatsink and two cages can be a PCIe X710-DA2, a Dell rNDC, an OCP 3.0 card, or a ConnectX-4 Lx. The edge connector is the part that has to match the slot, and it is the part sellers crop. PCIe gold fingers and a bracket screw mean a riser card. A mezzanine connector means NDC, rNDC, or FlexibleLOM. A small PCB with a pull tab means OCP 3.0. Ask for a photo of the edge if the title only says Intel 10Gb dual port.
The photo also hides the EEPROM in any optic left in the cage. An X520-SR2 with Cisco-coded modules can be a fine card and a useless pair of optics for your switch, or the other way around. It hides the bracket height. It hides I350 versus X710 when both are four RJ45 jacks and a black heatsink. It hides X540 versus X550 when the title says Intel dual 10GBase-T. The X550 is the one that will talk 2.5G and 5G. The X540 will not. It hides ACAT versus XCAT on a Mellanox label, which is the difference between a 25G-capable port and a 10G port.
Empty cages are normal on a DA2. The card is not dead because no optic was in the photo. It is incomplete until you have a DAC or a coded module for each port you intend to use. We test the NIC for link on the media it was built for. We ship the bracket that is on the card. If you need the other bracket, say so. If you need optics, they are a separate line, coded for the device you name.
What to send us
Send the chassis and the switch port on WhatsApp or Messenger. Those two facts pick the card.
- The server. R730, R740, R750, R760, DL380 Gen10, Gen11, a Supermicro H13 or H14, or a white box. Say whether the free slot is PCIe, NDC, rNDC, FlexibleLOM, or OCP 3.0. A 16G Dell and an EPYC Turin board can take a standard PCIe X710 in a riser and an OCP 3.0 NIC in the OCP bay. They are different orders.
- The switch port. SFP+, SFP28, or RJ45. SFP+ pairs with an X710-DA2, an X520-DA2 on Linux, or a ConnectX-4 Lx that will link at 10G. SFP28 is the MCX4121A-ACAT or an XXV710 if you want 25G now. RJ45 is an X550-T2 or an X710-T2L.
- The operating system. ESXi 8 pushes the order toward X710 or X550. Linux and TrueNAS are fine on the older X520 and X540 as well.
- Optics or DAC, if you need them. Name the switch vendor so the EEPROM matches, and name the NIC if it is a Dell-firmware X710 that checks Dell's list. SR or LR, and the length. Short in-rack runs should be DAC.
- Bracket height for a 1U. Low profile, or the full-height bracket the card already has.
The NICs and, when the run is fiber, the optics ship from Hong Kong after that check. We leave the firmware as it is. A retail X710 stays a retail X710. A Dell rNDC stays a Dell rNDC. A ConnectX-4 Lx on a 10G switch stays a 10G link, and we will say so before it ships rather than after the port is up.