ConnectX-3 is mlx4 and stops at FDR or 40GbE. MCX4121A-ACAT is SFP28 on mlx5, and a QSFP28 ConnectX-5 still needs the slot, the VPI mode, and the cable before the price means anything.
A used ConnectX that links on the bench and stays dark in the rack is usually the cage, the port mode, or the driver. The ASIC is rarely the part that died. The sticker is the whole order: which generation, which cage, whether the port can speak InfiniBand, and which PCIe generation the silicon can actually train.
In late 2026 a new leaf is 25GbE or 100GbE, and the host is often a 16G Dell, an HPE Gen11, or an EPYC Genoa, Bergamo, or Turin board. Those machines have OCP 3.0 beside ordinary PCIe, and the CPU is 4th or 5th Gen Xeon Scalable, Xeon 6, or SP5. The used pile is still full of ConnectX-3 cards that stop at 40GbE, and ConnectX-4 Lx cards that have no QSFP cage at all. DDR5 does not change the NIC. The slot and the bus do. Buy the card that matches the switch port and the opening you actually have free.
ConnectX-3 still speaks mlx4
ConnectX-3 and ConnectX-3 Pro use mlx4. The names you will see are mlx4_core, mlx4_en for Ethernet, and mlx4_ib for InfiniBand. That stack is finished. MLNX_OFED 5.x dropped ConnectX-3. The 4.9 line is the last OFED that still lists it. Installing a current NVIDIA host bundle will not bring mlx4 back. A current Ubuntu, Proxmox, or TrueNAS SCALE kernel may still raise the port with the inbox mlx4_en. That is a fair result on a 40GbE storage network you already run. It is a bad reason to start a new RoCE fabric, a new ESXi host, or a Windows Server 2022 box.
ESXi 8 has no inbox driver for these cards. The PCI device can show up and never become a vmnic. Windows Server 2022 and 2025 want WinOF-2, and WinOF-2 starts at ConnectX-4. The old WinOF package that knew mlx4 does not cover those releases. If the hypervisor is current, do not buy a ConnectX-3 because the bracket looks familiar and the price is lower than a ConnectX-4.
The card that still shows up in every pull is the MCX354A-FCBT. Dual QSFP, PCIe 3.0 x8, VPI. Each port can be FDR InfiniBand or 40GbE. You pick that with mlxconfig. It does not mean 100GbE. A QSFP28 module will seat in that cage, the latch will click, and the port is still a 40/56G port. The single-port twin is the MCX353A-FCBT. Same silicon, one cage. Ordering the dual-port card for a single uplink is harmless. Ordering it for an SFP+ or SFP28 switch is not. There is no small cage on an MCX354A.
ConnectX-3 Pro is the same generation with a later feature set, still mlx4. The Ethernet-only dual QSFP part we see is the MCX314A-BCCT. It can run 40GbE or 56GbE Ethernet. There is no InfiniBand mode to flip on. 56GbE here is a Mellanox-to-Mellanox rate, not a standard IEEE port. A Cisco or Arista QSFP+ port will link at 40G if you are lucky and configured, and it will not train at 56 just because the NIC allows it. A dual SFP+ ConnectX-3 Pro is a third order again: 10GbE only, small cages, and a worse fit for a new host than an Intel X710-DA2 that still has a current driver.
Lane width on this generation is easy to underestimate. One 40GbE port is 5 GB/s. PCIe 3.0 x8 is about 8 GB/s of payload, so a single port fits. Both ports of an MCX354A-FCBT driven flat out do not. The second link still comes up. A copy that fills both ports contends on the bus and gets blamed on the disk shelf. In an x4 slot it is worse. A Gen4 or Gen5 riser does not add lanes the card cannot train. ConnectX-3 stays PCIe 3.0.
VPI is a mode, not a speed
VPI means the port can be InfiniBand or Ethernet. It does not mean the port runs every speed printed on a newer module. On an MCX354A-FCBT the InfiniBand side is FDR, four lanes at 14 Gb/s, into an FDR switch such as an SX6036. The Ethernet side is 40GbE, four 10G lanes, into a QSFP+ port. None of that is EDR, and none of it is 100GbE. An EDR switch will not train an FDR card. An FDR switch will not train an EDR card. The cables can look identical in a photo of the pull tab.
A VPI card often ships, or was last used, in InfiniBand mode. You seat a good DAC into an Ethernet switch and the link stays down. mlxconfig is the fix, not a new cable. For port 1 the setting is LINK_TYPE_P1. Ethernet is 2. InfiniBand is 1. Port 2 is LINK_TYPE_P2. The value sits in NVRAM. The driver has to reload, and a lot of hosts want a reboot before ethtool shows a carrier. Until that happens, ibstat may show a port and the Ethernet interface never appears. A bench test that only ran ethtool will call the card dead.
On ConnectX-3 the same choice also shows up as mlx4_port1 under sysfs. Writing the mode there without a reboot can look like it worked and then revert on the next boot, because NVRAM was never updated. Set it with mlxconfig, reboot, and check ethtool. If the card is Ethernet-only, there is nothing to flip. The MCX314A-BCCT is Ethernet. A ConnectX-5 EN card such as the MCX516A-CCAT is Ethernet. The ECAT suffix, on the MCX455A-ECAT and the MCX556A-ECAT, is the VPI part. CCAT is 100GbE Ethernet. If you do not own an InfiniBand switch, buy the EN card and skip the mode bit. If you do own an IB fabric, the EN card will not join it.
HDR is the next line, and it is not these cards. ConnectX-6 uses a QSFP56 cage that looks like QSFP28 in a listing photo. MCX653106A-HDAT is the dual-port HDR card, 200 Gb/s InfiniBand and 200GbE. MCX653106A-ECAT is the dual-port QSFP56 card that stops at HDR100 and 100GbE. A ConnectX-5 in front of an HDR leaf stays down. A QSFP56 module seated in a ConnectX-5 cage does not create an HDR port. If the fabric is HDR, this article is the wrong order.
ConnectX-4 and the Lx cards
ConnectX-4 moved the driver to mlx5. That cut matters more than the badge on the heatsink. Inbox mlx5_core on a recent kernel brings Ethernet ports up on Linux, Proxmox, and TrueNAS SCALE. You do not need an OFED ISO for a plain Ethernet link. Install MLNX_OFED, or the current NVIDIA host bundle, when you need InfiniBand, a RoCE feature the inbox rdma-core build does not expose, or mlxconfig itself. Match that package to the kernel you actually boot. An old 4.x ISO on a 2026 kernel loads halfway, secure boot refuses the unsigned module, and the port never appears. ethtool -i shows the driver and the firmware. If the driver line says mlx4, you do not have a ConnectX-4.
ConnectX-4 Lx is the Ethernet part people mean when they say Mellanox 25GbE. MCX4121A-ACAT is dual SFP28, 10/25GbE, PCIe 3.0 x8. There is no QSFP cage on it. It takes a 10GbE SFP+ module or a 10G DAC and links at 10G. ethtool showing 10000 Mb/s is the card doing what the switch allows. It is not a failed 25G port. A 25G DAC or an SFP28 SR optic into an SFP+ switch usually stays down. The MCX4121A-XCAT is the dual SFP+ twin that is 10GbE only. ACAT can do 25G. XCAT stays at 10G even in an SFP28 switch. The single-port ACAT is the MCX4111A-ACAT. Read the last four letters, not the word ConnectX in the title.
HPE sells that Lx silicon under its own numbers, and the nearby Broadcom card is how the order goes wrong. The stand-up PCIe Mellanox card is the 640SFP28, spare 817753-B21, OPN MCX4121A-ACUT on the HPE sticker. The FlexibleLOM is the 640FLR-SFP28, spare 817749-B21, OPN MCX4121A-ACFT. Same cages, different edge. A 640FLR does not go in a riser. A retail MCX4121A-ACAT does not go in a Gen10 FlexibleLOM bay. The 631FLR-SFP28, spare 817709-B21, and the 631SFP28, spare 817718-B21, are Broadcom BCM57414. They look like the 640 in a photo of two SFP28 cages. The driver is bnxt_en, not mlx5. A listing that says HPE 10/25Gb 2-port SFP28 can be either family. Ask for the spare number, not the speed.
For 100GbE on ConnectX-4 you want a QSFP28 card, not an Lx. MCX455A-ECAT is the single-port VPI part, EDR InfiniBand or 100GbE, PCIe 3.0 x16. The dual-port VPI twin is the MCX456A-ECAT. One 100G port fits in a PCIe 3.0 x16 link, about 16 GB/s of payload against 12.5 GB/s of line rate. Two 100G ports are 25 GB/s. Both links come up. Both ports together contend, and a storage test blames the NIC. On a PCIe 3.0 host, buy the single-port 100G card unless you know the traffic will not fill both cages. Dual 25G on the MCX4121A-ACAT is what that x8 slot was built for. Drop it into an x4 slot and the two ports share a bus that is now tight.
ConnectX-5 and the Ex silicon
ConnectX-5 is still mlx5. The part numbers are not interchangeable with ConnectX-4 just because both say 100GbE on the box. MCX516A-CCAT is dual-port 100GbE Ethernet, QSFP28, PCIe 3.0 x16. MCX556A-ECAT is the dual-port VPI card, EDR or 100GbE, also PCIe 3.0. MCX515A-CCAT is the single-port Ethernet card when you only have one uplink. The 25GbE ConnectX-5 equivalent of the 4121 is the MCX512A-ACAT, dual SFP28, PCIe 3.0 x8. It also takes a 10G module and links at 10G. Buy it when you want a newer mlx5 card with 25G headroom, not because a listing said Mellanox dual port and the photo stopped at the heatsink.
ConnectX-5 Ex is the PCIe 4.0 silicon. MCX516A-CDAT is the dual-port 100GbE Ex card. In a PCIe 3.0 riser it enumerates and trains at Gen3. You paid for Gen4 lanes and the slot did not give them to you. In a PCIe 4.0 or PCIe 5.0 slot the card trains at Gen4, which is its ceiling. A Gen5 riser in an R760, on a Xeon 6 board, or on an EPYC Turin board does not make a ConnectX-5 Ex into a ConnectX-6 or a ConnectX-7. Dual 100GbE fits on PCIe 4.0 x16. It does not fit on PCIe 3.0 x16. That is the reason to pick the CDAT over the CCAT when the host is Milan or newer, and the reason a CDAT in an R740 still behaves like a Gen3 card.
Milan is SP3, PCIe 4.0, DDR4. Genoa, Bergamo, and Turin are SP5, PCIe 5.0, DDR5. A ConnectX-5 Ex is at home on both, at Gen4. A ConnectX-3 still runs, at Gen3, and it is still the wrong generation for a new fabric on those boards. 4th and 5th Gen Xeon Scalable, the Dell 16G and HPE Gen11 machines, are the same story on the Intel side: plenty of bus, an OCP 3.0 bay, and no magical speed-up for an older ASIC.
RoCE on these cards is a switch problem as much as a NIC problem. The mlx5 port can do RoCE v2. The fabric has to be lossless on the traffic class you use, which on a typical build means PFC and ECN on the leaf, not a checkbox on the card. A ConnectX-5 with a stock DAC will pass ordinary Ethernet with none of that. It will drop or pause under a heavy RoCE copy if the switch is still in a default lossy config. SR-IOV is a firmware bit, SRIOV_EN, set with mlxconfig before the kernel will split VFs. It is off on a lot of used pulls. Tell us if the card is for plain Ethernet, for RoCE, or for VFs. The part number can be the same. The firmware state is not something we flip during picking unless you ask and the image matches that PSID.
The slot in a late-2026 chassis
The CPU generation does not choose the NIC. The slot does. An MCX512A-ACAT and an MCX516A-CCAT are PCIe cards. They go in a riser. They do not fill a daughter-card bay, and a low-profile bracket does not change the edge connector.
Dell 12G and 13G, the R720 and R730, use a proprietary network daughter card. A ConnectX with a standard bracket does not mount there. It does fit a free riser if one is open. 14G, the R640 and R740, uses an rNDC. A Mellanox 25Gb rNDC is a different PCB from the MCX4121A-ACAT even when the cages match. 15G, the R650 and R750, drops the rNDC for OCP 3.0. 16G, the R660 and R760, 4th and 5th Gen Xeon Scalable, DDR5, keeps OCP 3.0. Xeon 6 platforms keep the same split: PCIe for the standard card, OCP 3.0 only when the NIC was built as an OCP card. An rNDC from an R740 does not fit an R750 or an R760.
The OCP card already in a 15G or 16G Dell is often a Broadcom 57414, dual 25GbE, not a ConnectX. The HPE 631 is that same Broadcom family in a FlexibleLOM or a stand-up card. Replacing the Dell OCP module means an OCP 3.0 NIC, or a standard ConnectX in a riser with the OCP bay left empty. Both are valid. They are different orders. OCP 2.0 is an earlier mezzanine and does not fit an OCP 3.0 slot. The screws and the connector both differ. A top-down photo of the chip hides that edge, which is how an OCP card gets sold as an MCX4121A-ACAT.
HPE Gen9 and Gen10 use FlexibleLOM. The 544+FLR-QSFP, 764285-B21, is ConnectX-3 Pro for that bay. The stand-up twin is 764284-B21. The 640FLR-SFP28, 817749-B21, is ConnectX-4 Lx. Gen10 Plus and Gen11 move to OCP 3.0. A FlexibleLOM card stays in the Gen10. Supermicro H12 boards are EPYC Milan, SP3, PCIe 4.0, and many have an OCP 3.0 slot beside normal PCIe. H13 and the Turin boards are SP5, PCIe 5.0, DDR5, same idea. A retail ConnectX fills a PCIe slot on those boards. It does not fill the OCP bay.
Bracket height is the 1U check. An R440, R640, or R650 riser wants the low-profile bracket. Used pulls usually have the full-height bracket screwed on, and the short one is missing from the bag. Ask. An OCP card and a FlexibleLOM have no PCIe bracket to swap. Ordering a short bracket does not turn them into a standard card.
Firmware, PSID, and OEM pulls
OEM cards keep an OEM PSID. The HPE 544+QSFP, 764284-B21, is ConnectX-3 Pro on a standard PCIe bracket. The FlexibleLOM version is 764285-B21. A generic Mellanox firmware image flashed over either of those can wipe the identity the server expects, and a half-written image does not enumerate. flint, or mstflint, prints the PSID and the current firmware. That printout is how you confirm the card. It is not a reason to cross-flash it on the bench before lunch.
We sell the card with the firmware it already has. We do not strip an HPE or Dell lock, and we do not change the PSID as part of the sale. In the original chassis the OEM image is the right image. Moved to a Supermicro or a white box, that same image can pause during POST while the option ROM looks for a vendor path that is not there. It can also boot Linux cleanly and still be the wrong firmware the day you open a vendor case. Tell us the chassis. A retail MCX card on Mellanox firmware is the one that moves between a Dell riser, a Supermicro slot, and a white box. A mezzanine with the same chip is a different piece of metal.
Old firmware is a separate problem from the wrong PSID. A ConnectX-4 or ConnectX-5 that has not been updated since it was pulled can refuse a 25G optic, fail a FEC negotiation, or come up with RoCE left disabled. A QSFP28-to-SFP28 adapter, the MAM1Q00A-QSA28, needs a ConnectX-4 Lx at firmware 14.18 or later and a ConnectX-5 at 16.18 or later before the card will even admit the adapter is there. We do not bump firmware during picking unless you ask and the image is the one for that exact PSID. Say so if the host is ESXi and you need a known production build. A file named ConnectX-5 firmware, downloaded because the version looked newer, is how these cards get bricked.
DAC, optics, and the switch that checks the code
Inside one rack, buy DAC. MCP2M00-A003 is a 3 m SFP28 cable for the MCX4121A-ACAT or the MCX512A-ACAT. MCP1600-C003 is a 3 m QSFP28 cable for a 100G port. It is thick enough to fight a cable arm. One meter is the better choice when the switch sits in the same rack. At 5 m, picky 100G ports start rejecting passive copper. That run wants an AOC, or a pair of optics and fiber.
Between racks, use optics. MMA2P00-AS is 25GbE SR, multimode, for an SFP28 cage. MMA1B00-C100D is 100GbE SR4, MPO, short multimode, for a QSFP28 cage. The ConnectX end is usually relaxed about third-party modules. The switch is the end that checks the EEPROM. Cisco Nexus, Dell OS10 on an S5248, and Aruba CX will leave a generic or wrong-coded module dark. Order the code that matches the switch. A module coded only as Cisco will often link in the ConnectX and fail in the Dell switch, or the other way around. We do not recode optics as part of the sale.
Match the cage before you match the code. An SFP28 DAC does not enter a QSFP28 port. A QSFP28 DAC does not enter an MCX4121A-ACAT. A QSFP28 optic in a ConnectX-3 QSFP cage does not create a 100G port. A MAM1Q00A-QSA28 lets one SFP28 or SFP+ module use lane 1 of a QSFP28 port. The other three lanes are dead. It is a way to land a single 25G or 10G link on a 100G card. It is not a way to get 100G out of an SFP module. Breakout from a 100G switch port is a switch setting plus a fanout cable, and the NIC end still has to be the connector on that cable.
What people order wrong
The expensive miss is a ConnectX-3 bought for a new 100G leaf. The QSFP shell matches. The port does not. The next miss is an MCX4121A-ACAT bought because the title said ConnectX-4 100GbE. Lx and ACAT means SFP28, 25GbE. There is no 100G cage on that card. The mirror image is an MCX516A-CCAT bought for a 25G SFP28 switch with a straight MCP1600 in the cart. The card is fine. The cable has the wrong plug on the only end that matters.
VPI cards get ordered for Ethernet and left in InfiniBand mode. EN cards get ordered for an FDR or EDR fabric and never join it. A PCIe 3.0 dual 100G card gets ordered for an R740 with the expectation that both ports will run full rate. They will not. A ConnectX-5 Ex gets ordered for that same R740 because the listing said PCIe 4.0. The slot is PCIe 3.0. The card trains down. An MCX653106A-HDAT gets ordered because the photo showed two QSFP cages and the word Mellanox. That card is HDR, QSFP56. It will not run HDR into an EDR leaf, and it is a different buy from a ConnectX-5 when the leaf is only 100GbE.
Form factor wastes the week. A 764285-B21 or an 817749-B21 looks, from above, like a NIC with two cages. It will not slide into the riser of the white box you are building. An OCP 3.0 card has no bracket. A low-profile MCX4121A-ACAT will not fill an OCP bay on an R760 just because both are small. The HPE 631 and the HPE 640 are both 25G and both SFP28, and only the 640 is mlx5. ESXi 8 plus a ConnectX-3 is the software version of the same mistake. The card posts. The vSwitch has no uplink.
What the listing photo hides
A heatsink and two metal cages can be a ConnectX-3, a ConnectX-4 Lx, a ConnectX-5, an HPE FlexibleLOM, a Dell rNDC, or an OCP 3.0 card. The edge is the part that has to match the slot, and it is the part sellers crop. PCIe gold fingers and a bracket screw mean a riser card. A mezzanine connector means FlexibleLOM, NDC, or rNDC. A small PCB with a pull tab means OCP 3.0. Ask for a photo of the edge if the title only says Mellanox dual port.
The photo also hides the last four letters of the OPN. ACAT versus XCAT is 25G versus 10G. ECAT versus CCAT is VPI versus Ethernet-only. ACFT is the HPE FlexibleLOM ConnectX-4 Lx, not a retail MCX4121A-ACAT. FCBT is the ConnectX-3 QSFP card, not a 100G card. It hides the bracket height. It hides whether the second cage exists, because a single-port MCX455A-ECAT and a dual-port MCX456A-ECAT share a heatsink shape in a tight crop. Empty cages are normal. The card is not dead because no optic was in the photo. It is incomplete until the DAC or the module for that cage is on the order.
We test the NIC for link on the media it was built for. We ship the bracket that is on the card. If you need the short bracket, say so before it leaves. Firmware stays as it is. A retail ConnectX-4 stays a retail ConnectX-4. An HPE 544+ stays an HPE 544+.
What to send us
Send the chassis and the switch port on WhatsApp or Messenger. Those two facts pick the card. The price on the NIC is the card. Optics and DAC are a separate line.
- The server. R740, R750, R760, DL380 Gen10, Gen11, a Supermicro H12 or H13, a Turin board, or a white box. Say whether the free slot is PCIe, rNDC, FlexibleLOM, or OCP 3.0. A 16G Dell and an EPYC Genoa or Turin board can take a standard ConnectX in a riser and an OCP NIC in the OCP bay. They are different parts. Xeon 6 does not change that split.
- The port you need. SFP28 at 10/25GbE is an MCX4121A-ACAT or an MCX512A-ACAT. QSFP28 at 100GbE is an MCX455A-ECAT, an MCX516A-CCAT, or an MCX516A-CDAT if the slot is PCIe 4.0 or 5.0 and you want both ports full. FDR or 40GbE on an existing fabric is the MCX354A-FCBT, and only if the OS still has mlx4.
- Ethernet or InfiniBand. VPI cards need the mode set. EN cards will not join an IB switch. Say if this is RoCE or SR-IOV, because the switch and the firmware bit matter as much as the OPN.
- The operating system and kernel. ESXi 8 wants mlx5, ConnectX-4 or newer. Linux and TrueNAS are fine on inbox mlx5 for Ethernet. A ConnectX-3 on a current kernel is a conversation, not a default.
- The cable. In-rack 25G is an MCP2M00 at 1 m or 3 m. In-rack 100G is an MCP1600. Longer runs are optics, coded for the switch. Name the switch vendor. A MAM1Q00A-QSA28 is a one-lane adapter, not a 100G optic.
- Bracket height for a 1U, and a photo of the edge if you are replacing a mezzanine rather than filling an empty riser. If the spare in the chassis today is an HPE 631, say so. That is Broadcom, and the replacement Mellanox is the 640 or a retail MCX, not another 631.
We confirm the cage, the PSID family, and the cable, then ship from Hong Kong. A ConnectX-3 stays a 40G or FDR card. A ConnectX-4 Lx stays an SFP28 card. A dual 100G ConnectX-5 in a PCIe 3.0 riser stays a Gen3 bus. We will say which of those you are buying before it ships.