SFP+, SFP28, and QSFP28: cages, codes, and breakout
SFP+ and SFP28 share a cage and not a speed. QSFP+ and QSFP28 share a shell. The EEPROM code, FEC, and the breakout cable decide whether a used module actually links.
Look at the cage on the bracket before you read the speed printed on the module. The shell tells you what can physically latch. The EEPROM and the port speed tell you whether that latch means a link. A used optic that passed on someone else's switch stays dark in yours for one of those two reasons, and almost never because the laser is dead.
In late 2026 the new access port is SFP28 at 25G, and the new uplink is QSFP28 at 100G, often broken out to four 25G hosts. A 16G Dell, an HPE Gen11, and an EPYC Genoa, Bergamo, or Turin board can take a 100GbE card in a PCIe 5.0 riser or an OCP 3.0 NIC in the OCP bay. A lot of switches already on the floor are still SFP+ or QSFP+. The module has to match the port you have, not the port you plan to buy next year. DDR5 and Xeon 6 do not change the cage.
The cage is the first filter
SFP+ and SFP28 use the small cage. The bail latch is the same shape. QSFP+ and QSFP28 use the wide cage and a pull tab. A QSFP shell will not enter an SFP port. An SFP module will not latch in a QSFP port. Forcing either one bends the cage, and a bent cage fails the next good module that would have fit.
An X710-DA2 stays a 10GbE card. Two small cages do not become 25G because the DAC in your hand says SFP28. An MCX4121A-ACAT, the dual SFP28 ConnectX-4 Lx, stays a 25G card. It does not grow a QSFP28 port. An MCX516A-CCAT or an Intel E810-CQDA2 has the wide cage. A straight QSFP28 DAC is the cable that belongs there. A straight QSFP28 DAC in front of an MCX4121A-ACAT is the wrong connector on the only end that matters.
Two other shells show up in late-2026 listings and do not fit these cages. QSFP-DD is the longer 200G and 400G module. A QSFP28 port will not accept it. An OSFP module, the shell on a lot of 400G ConnectX-7 cards and on NVIDIA Quantum and Spectrum 400G ports, is a different rectangle again. It will not enter a QSFP28 cage on a ConnectX-5. The reverse direction is the one that works on purpose: a QSFP-DD switch port will often take a QSFP28 optic and run it at 100G. That does not make your old QSFP+ switch into a 400G switch, and it does not make a QSFP-DD module fit the NIC you already own.
SFP+ and SFP28
SFP+ is 10GbE. That is the cage on an X520-DA2 and an X710-DA2. The electrical spec is one 10G lane. SFP28 is 25GbE, same metal, a faster electrical spec, nominally 28G so the encoded 25G stream fits. An XXV710-DA2 and a ConnectX-4 Lx MCX4121A-ACAT are SFP28 cards. A ConnectX-5 MCX512A-ACAT is the same cage on newer silicon. Intel's E810-XXVDA2 is the later 25G card, ice driver, still the small cage.
An SFP28 port will usually bring up a 10GbE SFP+ module or a 10G DAC, and the link is 10G. ethtool showing 10000 Mb/s is the fallback working. It is not a broken 25G port. The other direction fails quietly. An SFP+ switch port does not train at 25G because the DAC says SFP28 on the pull tab. Some dual-rate cables fall back to 10G. A pure 25G DAC usually leaves the port down. Buy the 10G cable when the switch is 10G. Buy the 25G cable when both ends are SFP28 and you want the higher rate.
The MCX4121A-XCAT is the trap inside the same family. It is ConnectX-4 Lx with SFP+ cages, 10GbE only. The last four letters are the product. ACAT can do 25G. XCAT cannot, even if you plug in an SFP28 optic and the switch is a Nexus 93180 or a Dell S5248. The module may be recognized. The link will not come up at 25G. There is no firmware flag that turns an XCAT into an ACAT.
Reach on the small cage is not one number. 10GBASE-SR on OM3 is about 300 m, and about 400 m on OM4. 25GBASE-SR is much shorter: about 70 m on OM3 and 100 m on OM4. A plant that was designed for 10G SR, with 150 m of OM3 between rooms, will light a 10G optic and stay dark with a 25G SR optic in the same patch. That looks like a bad module. It is the reach. 10GBASE-LR and 25G LR are both 10 km on OS2, duplex LC, 1310 nm. Both ends have to be the same optic type. An SR module on a singlemode patch stays dark. An LR module on a short multimode jumper stays dark. Wavelength is not optional.
QSFP+ and QSFP28
QSFP+ is 40GbE, four 10G lanes. QSFP28 is 100GbE, four 25G lanes. The shells match, which is why this mistake is common. The heatsink, the pull tab, and the dust cap all look the same in a dealer photo. The electrical generation does not. A QSFP28 module seated in a QSFP+ switch port does not make that port 100G. The ASIC behind the cage is still a 40G port. A QSFP+ module in a QSFP28 NIC, an E810-CQDA2 or a ConnectX-5 MCX516A-CCAT, often links at 40G if the card allows the lower rate. Budget the lower rate. Do not budget 100G.
The same shell also covers parts that are not four-lane 100G. A 50GbE port, two 25G lanes, still uses a QSFP28 cage. ConnectX-4 and ConnectX-5 have 50G OPNs. A cable that splits 100G into 2x50G, such as the MCP7H00-G003, has a QSFP28 plug on every leg. That plug will not enter an SFP28 NIC. It will click into a 100G port that has not been set to 2x50 and still stay down. Read the split, not just the shell.
ConnectX-3 is the older wide cage. The MCX354A-FCBT is dual QSFP, FDR InfiniBand or 40GbE, PCIe 3.0 x8. A QSFP28 module fits in that cage. The port is still 40/56G. FDR is four 14G lanes into an FDR switch, not EDR and not 100G. People buy a used 100G SR4 optic for this card because the listing photo of the NIC showed a QSFP pull tab. The optic is fine. The card cannot use it at 100G.
Connector face is the other half of the wide cage, and the dust cap hides it. 100GBASE-SR4, the MMA1B00-C100D and the Cisco QSFP-100G-SR4-S, is MPO-12. It uses eight of the twelve fibers, four transmit and four receive. 100GBASE-LR4 and 100GBASE-CWDM4 are duplex LC. A 100G BiDi such as the Cisco QSFP-100G-SRBD is also duplex LC, multimode, and it only links to another BiDi. SR4 will not link to LR4. SR4 will not link to BiDi. CWDM4 will not link to LR4 even though both are duplex LC singlemode, because the wavelengths and the reach are different. CWDM4 is about 2 km. LR4 is about 10 km. PSM4 is MPO again, but singlemode, about 500 m. The patch panel has to match the face, not the speed printed on the pull tab.
A faster module in a slower port
Fallback only runs one direction, and only when the slower rate is one the port already knows. SFP28 port plus SFP+ module is 10G. QSFP28 port plus QSFP+ module is often 40G. SFP+ port plus a 25G-only module is down. QSFP+ port plus a 100G-only module is down, or it links at 40G on a module that happens to speak 40G. Most 100G SR4 optics do not speak 40G. Assume they do not, and test before you count on it.
There is a mechanical cheat, and it is one lane. The MAM1Q00A-QSA28 is a QSFP28 shell with an SFP28 receptacle inside. Lane 1 passes through. The other three lanes are not connected. You get 25G, or 10G with an SFP+ module, out of a 100G cage. You do not get 100G, and you do not get 40G. The older MAM1Q00A-QSA is the blue-tab 40G-to-10G adapter. The Cisco part for that older job is the CVR-QSFP-SFP10G. A QSA28 in a ConnectX-4 Lx wants firmware from the 14.18 line or later. A ConnectX-5 wants 16.18 or later. Older firmware rejects the adapter EEPROM and the SFP never shows up in ethtool. The card looks empty. The adapter is not defective.
New 100G optics from the last few years add another miss. 100G-DR and 100G-FR are single-lambda modules on duplex LC. Cisco sells them as QSFP-100G-DR-S and QSFP-100G-FR-S. DR is about 500 m of singlemode. FR is about 2 km. They will not link to an SR4, and they will not link to an LR4. A 2026 leaf that shipped with DR ports, and a used MMA1B00-C100D on MPO, is a dark link with two perfectly good parts. Match the optic generation at both ends. Single-lambda to single-lambda, or SR4 to SR4. Do not mix them because both labels say 100G.
A 10GBASE-T module in an SFP+ cage is the copper version of the same idea. It is a small PHY in a metal shell, it runs hot, the reach is often 30 m on Cat6a, and a lot of X710 firmware rejects it as an unsupported transceiver. The port stays down. If both ends of the run are RJ45, buy a copper NIC. Keep the SFP+ cage for DAC and fiber.
Vendor coding
The module EEPROM carries a vendor name, a part number, and a compliance code. Switches enforce the name. NICs are looser, and they are not all equally loose. The code you buy is the code of the device the module is about to enter. A pair of optics is not one code. Each end is coded for its own host.
Cisco Nexus is the strict case. A generic or Arista-coded 10G SR stays dark in a Nexus unless that box already allows unsupported transceivers, and a lot of production switches do not. The log says unsupported transceiver. The laser can be fine. Dell OS10 on an S4148 or an S5248 is the same story. Older FTOS, the S4048-ON generation, sometimes still has a command to permit an unsupported module. Do not assume the OS10 switch inherited it. Aruba CX will not ignore a Cisco-coded optic. HPE Comware on older FlexFabric gear can suppress the alarm. Juniper QFX keeps its own list. NVIDIA Spectrum switches, an SN2410 or an SN2700, are often happier with a LinkX module such as the MMA2P00-AS or the MMA1B00-C100D than with a Cisco-coded SR4. Coding for Cisco does not satisfy Dell, and coding for Dell does not satisfy Aruba.
On the server, an X520 will usually link a generic SR optic that follows the SFP MSA. An X710 checks the vendor string harder. A used Cisco SFP-10G-SR is often rejected. The kernel log says unsupported SFP. A module whose EEPROM says Intel, such as an E10GSFPSR or a compatible coded that way, is the one that links in a retail X710. ConnectX-4 and ConnectX-5 are looser than the X710. They will often accept the module the switch just refused, which is why the link comes up on the host and stays down on the leaf. Dell-firmware NICs, including a lot of 14G rNDC modules, can insist on Dell's list. Intel coding is not automatically Dell coding. We do not cross-flash NIC firmware, and we do not recode modules as part of the sale.
Used labels lie. A Cisco sticker can be left over from a recode, and a blank label can still be Cisco inside. A module that was coded for the switch it came out of will not announce that on the housing if someone swapped the pull tab. ethtool -m on the NIC, or the switch transceiver detail, prints the vendor string the EEPROM actually holds. If the listing does not name the coded vendor, ask before you count on the optic for a storage VLAN. If we do not know the code, we will say so. We will not guess from the color of the latch.
Breakout is a switch setting
Breakout is a switch setting plus a fanout cable. It is not a feature of the NIC, and it is not something the cable does by itself. A QSFP28 port left at 1x100G will not light four SFP28 ends. A port already broken out to 4x25G will not light a straight 100G DAC. The cable and the port mode have to be the same shape.
A QSFP28 port set to 4x25G wants a cable like the MCP7F00-A002R30N, 2 m, QSFP28 on the switch end and four SFP28 ends. Those four ends land on SFP28 NICs: an MCX4121A-ACAT, an XXV710-DA2, an MCX512A-ACAT. They do not land on a QSFP28 NIC. The 40G version of the same idea is a QSFP-4SFP10G-CU3M, one QSFP+ to four SFP+, 3 m. That is the cable for a 40G port broken out to four 10G servers, or for a 100G port that the switch will actually run as 4x10G. Not every 100G port offers 4x10. Ask the switch, not the cable jacket.
MCP7H00-G003 looks related on a shelf and is a different split. 100GbE to 2x50GbE, QSFP28 on every leg, 3 m. Both far ends need a QSFP28 port that can run 50G. An SFP28 NIC cannot take the plug. A 100G NIC left at 100G will not train one leg of this cable as a full 100G link. The 2 m and 3 m lengths are for inside the rack or the next rack over. They are stiff. A 2 m 4x25G breakout has four twinax legs. Plan the cable arm before you order a second one, because two of them fill a 1U side channel.
The usual late-2026 leaf is a 100G port broken out to four 25G hosts, or a native SFP28 downlinks switch with 100G uplinks. Dell S5248F-ON, Cisco Nexus 93180YC, and NVIDIA SN2410 are that second shape: SFP28 to the server, QSFP28 toward the spine. You do not need a breakout cable for the server port on those switches. You need an SFP28 DAC or an SFP28 optic. Ordering a fanout because the spine is 100G is how a rack of MCX4121A-ACAT cards stays dark while a perfectly good MCP7F00 sits coiled on the tile. The fanout belongs on the 100G port that was configured as 4x25, and nowhere else.
DAC length, AOC, and fiber
Passive DAC at 1 m or 3 m is the in-rack cable. MCP2M00-A003 is the 3 m SFP28 DAC. MCP1600-C003 is the 3 m QSFP28 100G DAC, and it is the stiff one. One meter is the better buy when the switch and the server are in the same rack. The cable is cheaper, it pulls less, and fewer ports argue with it. At 5 m, picky 100G switch ports start rejecting passive copper. Some 25G ports do the same. That length is an AOC, or a pair of SR modules and fiber. Seven meters of passive 10G DAC exists and is already the point where a strict switch says no. Do not stretch a 100G passive DAC to make that run.
AOC is the middle distance. It is an optical cable with the modules built onto the ends, usually 3 m to 30 m for 25G and 100G. There is no EEPROM choice to get wrong in the middle, and there is also no way to recode one end for a different vendor. Both ends are the code that was written at the factory. A Cisco-coded AOC into a Dell OS10 switch fails the same way a Cisco optic does. Order the AOC for the stricter end, and check that the other end will accept it. A ConnectX will usually accept an AOC that a Nexus refuses. An X710 might not.
Fiber is the long run and the run between rooms. Short reach multimode is 10G SR on OM3 or OM4, 25G SR with the shorter limits above, or 100G SR4 on MPO. Ten kilometres is LR or LR4 on OS2, duplex LC, the same reach at both ends. BiDi modules only work as a matched pair, opposite wavelengths. A 10G BiDi pair is two different part numbers, not two of the same module. Buying two identical BiDi optics because the listing was a quantity discount leaves both ports down. Singlemode patches are duplex LC with a polarity that has to cross. If both ends transmit on the same fiber, each receiver sees silence. Swap the pair at one end before you swap the optic.
Power follows the module. A passive DAC is the cool path. An SR optic is next. LR4 and CWDM4 draw more, and a 10GBASE-T SFP is the heater. A switch has a per-port and per-tray power budget. Filling every port of a 1U 100G leaf with high-power LR4 modules can hit that budget even when each module is within its own spec. DAC on the short ports and optics only where the distance requires them is the layout that stays inside it.
FEC, MPO polarity, and a dark port
25G and 100G often need forward error correction before the link is allowed to come up. 10G usually does not. A port with FEC disabled will not light a 100GBASE-SR4 or a 25GBASE-SR optic that requires RS-FEC. The module is seated, the EEPROM reads, Rx power may even show up, and the link stays down. ethtool --show-fec on the NIC, and the matching switch command, are the check. RS-FEC is the mode those SR optics want. Firecode, the older BASE-R FEC, is what some short 25G copper settings still use. Off is what a 10G port expects. A mismatch looks exactly like a bad cable.
Auto-negotiation is less reliable at 25G than it was at 10G. A DAC that linked by itself on a lab switch can sit down on a port that is hard-set to the wrong FEC or the wrong speed. Set both ends the same way. If one end auto-negotiates and the other is forced, you can get a link at 10G on a pair of 25G ports and spend an afternoon blaming the NIC. Read the negotiated speed. Do not trust the link light alone.
MPO polarity and pins are the 100G SR4 failure we see after the EEPROM is already correct. The module is usually pinned. The cable has to be the unpinned mate. Two pinned connectors will not seat, and forcing them bends the pins. The next module then fails in a cage that used to work. Type B polarity is the usual patch for a single SR4 link so that transmit on one end lands on receive on the other. A Type A trunk in the middle of that path flips the rule. A link that works with a 1 m MPO jumper on the bench and fails through the building trunk is polarity, not a dead MMA1B00-C100D. Eight fibers are in use. A dirty end-face on one of them drops a lane, and some ports refuse to come up with a lane missing. Clean the MPO before you replace the optic. A scratched singlemode ferrule is the LR version of the same story: it can pass a 2 m patch on the bench and fail at 4 km.
ethtool -m is worth running before the second optic goes in the cart. It prints the vendor string, the wavelength, and DOM if the module supports it. Temperature, Tx power, and Rx power tell you whether light is arriving. No Rx power means the far end is down, the fiber is crossed or broken, or you are on the wrong polarity. Rx power present and the link still down points at FEC, speed, or coding, not at a dark fiber. A switch log that says unsupported transceiver points at coding and nothing else. Replace the code, not the fiber.
What people order wrong
The common order is a 25G DAC for a pure SFP+ switch, with the expectation that the port will become 25G. It will not. The next is a QSFP28 optic for a QSFP+ switch, same expectation at 100G. Then a 100G SR4, MPO, ordered for a patch panel that is duplex LC all the way to the other row. The optic is the right speed and the wrong face. CWDM4 or LR4 is the LC part. SR4 is the MPO part. BiDi is LC too, and only as a matched pair.
Coding is the quiet one. A Cisco-coded SFP-10G-SR for a Dell OS10 leaf, an Arista-coded 25G SR for a Nexus, a generic 100G SR4 for an Aruba CX port that has never been told to allow it. The NIC will often link the same module, so the test on the server passes and the maintenance window fails. Breakout cables get ordered when the switch port is a native SFP28, and straight QSFP28 DACs get ordered when the port is already in 4x25. A MAM1Q00A-QSA28 gets ordered as if it turned one SFP28 NIC into a 100G NIC. It turns a 100G cage into a single 25G or 10G port.
The chassis still matters, because the cage is mounted on a card that has to fit the slot. An OCP 3.0 NIC in an R760 or a Gen11 DL380 is not a standard X710-DA2, even when both have two SFP28 or SFP+ openings. A FlexibleLOM and a Dell rNDC are the previous generation of that mistake. The module can be perfect and the card still will not mount. Send the slot with the optic order. A QSFP-DD or OSFP module bought because the title said 400G will not enter the QSFP28 cage on the MCX516A-CCAT you already have.
What the listing photo hides
A dust cap on a metal shell can be SFP+ or SFP28, QSFP+ or QSFP28, MPO or LC, BiDi or SR4. The pull-tab color is not a standard. Some vendors dye the latch. Most compatible modules do not. A blue tab is not reliably 10G LR, and a black tab is not reliably 25G. Read the label, then confirm the EEPROM, because the label on a used module is the least reliable line on the part.
The photo hides the vendor string. It hides a Cisco sticker left after a recode. It hides the second connector on a breakout, because sellers photograph the QSFP28 end and crop the four SFP28 legs, or the other way around. It hides length. A 1 m DAC and a 5 m DAC are the same plug, and the 5 m passive 100G lead is the one a strict switch will reject. It hides pins on an MPO. It hides whether the module is DR or SR4 when both are sold as 100G QSFP.
Empty cages on a NIC are normal. The card is not incomplete in the photo. It is incomplete on the order until each port you intend to use has a DAC or a coded module. We do not recode, and we do not describe a module as Cisco unless the EEPROM says Cisco. If the listing you are comparing against does not name the code, treat that optic as unknown. Unknown is how a storage link stays down on a Saturday.
What to send us
Send the switch model and the NIC part number on WhatsApp or Messenger. Those two lines pick the cage, the speed, and the EEPROM code. The NIC and the optic are separate lines. We match them, then ship from Hong Kong.
- The switch port, exactly. SFP+, SFP28, QSFP+, or QSFP28, and whether that port is still in 1x100, 4x25, 4x10, or 2x50. A Nexus 93180YC or an S5248F-ON downlink is SFP28. A breakout only exists if you configured it.
- The NIC. X710-DA2 and X520-DA2 take SFP+. XXV710-DA2, MCX4121A-ACAT, and MCX512A-ACAT take SFP28 and will fall back to 10G. E810-CQDA2 and MCX516A-CCAT take QSFP28. An HPE 640FLR or a Dell OCP 3.0 card is a different order from a standard PCIe NIC even when the cage matches. Say if the host is a 16G Dell, a Gen11, or an EPYC Turin board, and which bay is free.
- The code. Cisco, Dell, Arista, Aruba, Juniper, or NVIDIA. Name the end the module sits in. A module for the switch is coded for the switch. A module for a retail X710 is coded Intel. We do not recode either one.
- The medium and the length. Passive DAC at 1 m or 3 m inside the rack. AOC or SR optics past the point where passive copper gets refused. SR, LR, CWDM4, or DR, and whether the patch is LC or MPO. Both ends the same optic type. BiDi only as a pair.
- FEC if you already know the switch is forced. RS-FEC for 25G SR and 100G SR4. A port hard-set to FEC off will not light those modules.
A QSFP28 shell in a QSFP+ port stays a 40G port. An SFP28 DAC in an SFP+ port stays down unless that cable can fall back, and then the link is 10G. A breakout cable does nothing until the switch port is broken out to match it. We would rather confirm that on the message than ship a module that cannot link in the cage you have.