Guides
Which used NIC ESXi will actually see
On ESXi 8 an X710-DA2 still becomes a vmnic. An X520, a 57810 daughtercard, and a ConnectX-3 often enumerate and then never produce a port.
The NIC that becomes a vmnic is the one whose driver is still in that ESXi build. The chipset name on the heatsink is not the test. Match the PCI device ID, the subsystem ID, and the form factor to the image you actually boot. A card that linked for years on ESXi 6.7 can sit in the PCI list on ESXi 8 and never produce a port. By late 2026 that is the usual failure we see, because ESXi 7 general support ended in 2025 and a new cluster is an 8.x image.
We sell used NICs from Hong Kong against the server and the build you already run. A Dell rNDC, an OCP 3.0 module, and a standard PCIe card can share a chip and still be three different orders. The photo of the heatsink is how those get mixed.
X710 is the safe used buy
For ESXi 7 and ESXi 8, start with the Intel X710. The inbox driver is i40en. An X710-DA2 is the dual SFP+ card, PCIe 3.0 x8. An X710-DA4 is the quad-port version, longer, hotter, and hungrier. The device ID people quote for the SFP cards is 8086:1572. That ID is the start of the HCL line, not the whole line. VMware's entry is vendor, device, subvendor, and subdevice, plus a firmware and a driver VIB. A Dell X710 rNDC and a retail X710-DA2 share the chip and can still differ on the subsystem ID that was listed.
The XXV710-DA2 is the 25GbE part in the same family, SFP28 cages, still i40en. Buy it when the switch ports are SFP28. In an SFP+ switch it can still link at 10G with a 10G optic or a 10G DAC, and that is the speed you get. It does not turn a 10G switch port into 25G. The X710-T2L and X710-T4 are the RJ45 cards in this generation. They belong on a copper plant. They do not take an optic.
On a 14th-gen Dell the same silicon often shows up as an rNDC, the daughtercard in the dedicated network slot of an R640 or an R740. It is not a PCIe card with the bracket unscrewed. The latch, the connector, and the placement are Dell's. An R740 rNDC does not screw into a Supermicro riser. A retail X710-DA2 does not fill an empty rNDC bay. Ask for the OEM part number on the sticker before you assume the shape.
X550 still, X520 and X540 mostly not
Copper runs that are not X710-T cards usually want an X550-T2. It is 10GBASE-T, PCIe 3.0, and the inbox driver is still there on current ESXi 8 images we see in the field. The device ID is 8086:1563. It draws less than the older X540-T2 and it runs cooler in a packed 1U. It is still a 10GBASE-T card. It will not light an SFP+ switch.
X520-DA2 and X540-T2 are the parts that bite people. They were the default 10GbE NIC for years. The X520-DA2 is 82599 silicon, device ID 8086:10fb, PCIe 2.0, driver ixgben when that driver exists. The X540-T2 is 8086:1528, also the ixgbe family, dual RJ45, and it runs hot. Both still link on ESXi 6.7 and on a lot of 7.0 hosts. ESXi 8 dropped native support for many of those 82599 and X540 device IDs. The box boots, the PCI device is visible, and no vmnic appears. A community VIB or an OEM image can put a driver back. That VIB is your project. We do not inject VIBs, and the next upgrade is how the port disappears again. On ESXi 8, buy an X520 or an X540 only after that exact PCI ID has already been proven on your image.
HPE's 560FLR-SFP+ and 560SFP+ are 82599 FlexibleLOM modules. They fail the same way on ESXi 8, and they only fit the FlexibleLOM slot on the Gen9 or Gen10 they came from. The 562FLR-SFP+ is the X710 FlexibleLOM. That one is the HPE part that still has a chance on a current image, inside the ProLiant that has the slot. Neither module becomes a PCIe card.
E810, and the firmware it wants
E810 cards out of R650, R750, and R760 hosts come up on a late ESXi 7 image or on ESXi 8, driver icen. The dual 25GbE pull is the E810-XXVDA2. The 100GbE pull is the E810-CQDA2, QSFP28, not SFP+. The slot on the retail cards is PCIe 4.0. In an R740, which is PCIe 3.0, the link trains down. The port can still pass traffic. You do not get the Gen4 bandwidth the card was built for, and a dual 100G card in a Gen3 x16 slot is a compromise you should make on purpose.
Firmware is the other half. icen is picky about NVM. A card pulled early in the 15G cycle can enumerate and then fail to attach until the NVM is a build the driver accepts. We can tell you the firmware family on the unit we have. We do not promise a cross-flash from a Dell personality to a retail Intel image. Dell-branded E810 modules in 15G and 16G are usually OCP 3.0, not PCIe. An OCP 3.0 card does not fit a standard slot, and a PCIe E810-XXVDA2 does not fit the OCP bay on an R750 or an R760. HPE Gen11 and EPYC Genoa or Turin boards grew the same OCP bay. The slot is for the NIC. It is not a place to park an HBA, and it is not interchangeable with a 14G rNDC or a Gen10 FlexibleLOM.
Where X520-class silicon still hides
Onboard LAN is a separate order from the card you think you are buying. 14th-gen Dell and the Supermicro X11 boards use the Lewisburg chipset LAN, the X722, which attaches with i40en. It is part of the motherboard. A used X520 in the riser does not replace it, and a dead X722 port is not fixed by a driver you add for the 82599. On ESXi 8 the onboard X722 is often the port that still appears when the added X520 does not.
1GbE is dull and still useful. An Intel I350-T4 attaches with igbn on ESXi 7 and 8. The quad-port card is a normal spare for management and for a vMotion VLAN that never needed 10G. The I350 is PCIe 2.0. Do not buy it as a storage NIC. Broadcom BCM5720 ports soldered to Dell and HPE boards are the same kind of part, driver ntg3, and they stay with the motherboard. A listing that says Dell quad-port 1GbE is often an I350 mezzanine or rNDC, not a PCIe I350-T4. The sticker decides.
Solarflare and Chelsio cards still show up in low-latency pulls. A Solarflare X2522 wants its own driver and Onload. It is not an inbox vmnic on ESXi 8. A Chelsio T520 or T580 is the same story, cxgb4 on Linux and a driver ESXi 8 does not ship. If the heatsink says Solarflare or Chelsio, do not plan the vSwitch around it.
Broadcom 57416 versus 57810
Broadcom splits in two, and the split is the generation. The 57416, 57414, and 57412 are NetXtreme-E. The ESXi driver is bnxtnet, and it is inbox on ESXi 7 and 8 for a lot of those device IDs. A 57416 rNDC from a 14th-gen Dell is a fair card in another 14th-gen Dell when the firmware matches that generation. Move it to a generic host and you can get link flaps, or a driver that loads and then passes nothing. The option ROM and the firmware personality want the OEM path. We do not strip that personality.
Older 57810 and 57800 daughtercards use bnx2x. A lot of those device IDs are absent from the ESXi 8 native driver. The box sees the PCI device. No vmnic. A listing that says Dell 10Gb dual-port, with no chip name, is often a 57810 or a QLogic-branded twin of the same silicon. QLogic 57810 and Broadcom 57810 are the same era. HPE FlexFabric adapters, the 534 and 556 class, are a different ASIC again, and the driver story on a current ESXi image is worse than an X710. They are at home in the ProLiant they were qualified for, on the HPE custom image, and awkward everywhere else.
A 57414 OCP card from a 15G or 16G Dell is not the 14G rNDC. The metal is smaller, the connector is the OCP edge, and the pull tab is not a PCIe bracket. People order it because the title said Broadcom 10Gb or 25Gb. It arrives, and it does not fit the riser. Send a photo of the slot, not just the speed.
Mellanox that ESXi 8 still drives
ConnectX-4, ConnectX-5, and ConnectX-6 use nmlx5 on ESXi 7 and 8. A retail MCX4121A-ACAT is the ConnectX-4 Lx dual 25GbE card. A retail MCX512A-ACAT is the ConnectX-5 dual 25GbE card. Both move between boards more cleanly than a Dell-firmware X710 rNDC, as long as the card itself is on Mellanox firmware rather than an OEM personality. A ConnectX-4 or ConnectX-5 in Dell or HPE firmware may want that OEM's slot. We sell the firmware that is on the card. We do not cross-flash OEM to retail.
ConnectX-3 is finished on ESXi. The card everyone still has in a drawer is the MCX354A-FCBT, dual QSFP, VPI, 40GbE or FDR InfiniBand. The driver was mlx4. ESXi 7 dropped it from the inbox image, and ESXi 8 does not bring it back. The PCI device shows up. There is no vmnic. A QSFP28 module will seat in that cage and the port is still a 40G port. Do not buy a ConnectX-3 for a new ESXi 8 host. A ConnectX-6 on Mellanox firmware is the 100G card that still attaches. A ConnectX-7 is a newer pull. Check the exact PCI ID against your image before you count on it. The OCP ConnectX-6 Lx modules from R750 and R760 pulls are OCP 3.0. They do not fit a PCIe slot.
InfiniBand mode is a separate miss. A VPI card left in IB mode will not give you an Ethernet vmnic until the port personality is Ethernet. That setting lives in the card. If you need Ethernet and the listing does not say the port is already EN, ask. We can read the mode on the units we test. We do not treat a mode change as a free rewrite of every VPI card on the shelf.
Form factor before the driver
The driver question is useless if the card cannot be screwed in. Four shapes cover almost every used pull we ship.
- Standard PCIe, full height or low profile. A retail X710-DA2, a retail MCX512A-ACAT, an E810-XXVDA2. This is the card for a white box, a Supermicro riser, or an empty Dell slot.
- Dell rNDC, 13th-gen and 14th-gen. R630, R730, R640, R740. It does not fit 15G or 16G.
- OCP 3.0. Dell R650, R750, R660, R760. HPE Gen10 Plus and Gen11. EPYC Genoa, Bergamo, and Turin boards that grew an OCP bay. The screw pattern and the edge connector are not PCIe.
- HPE FlexibleLOM. Gen9 and Gen10. 560FLR, 562FLR, and the FlexFabric modules. Gen11 does not take them.
A 1U also cares about the bracket. An X710-DA4 is a full-height card and a tight fit. An X710-DA2 with the low-profile bracket in the bag is the usual 1U part. Say the chassis height when you order. A card that tests fine and cannot be screwed into the slot is still the wrong shipment.
Media, FEC, and the offload you can skip
Match the media to the switch, then match the optic to the port that is strict. SFP+ wants a DAC or a 10G-SR / 10G-LR the port will accept. X540 and X550 want copper. An Intel X520 or X710 will usually link with a generic SR optic that follows the SFP MSA. Some 82599 firmware still carries the old Intel whitelist, and a generic module stays dark until the driver is allowed to ignore it. ESXi is a poor place to find that knob. If the optic matters, use a module the card has already linked, or move the strict end of the cable to a switch you know how to code for. Dell OS10 and Aruba CX are the strict ends. The NIC usually is not. That fight is the optic's problem, and it is why a tested NIC can still look dead on Monday.
25GbE adds FEC. A correctly coded SFP28 can still fail, or it can link and drop frames, if the switch port and the NIC disagree on RS-FEC, firecode, or FEC left off. Check the switch port before you order a second card. 10GbE SR and LR do not use that FEC dance. Turning FEC settings over a dark 10G link does not fix a coding mismatch.
Skip the upsell for iSCSI offload, FCoE, and TOE. On ESXi the software initiator, pinned to a stable vmnic, is the setup that survives the next upgrade. Hardware offload on a 57810 or a FlexFabric card is how a datastore disappears when the driver does. SR-IOV is real on X710, E810, and ConnectX-5, and it is a feature you turn on after the vmnic exists. It is not a reason to buy a card the image cannot see.
What the listing photo hides
The photo shows a heatsink and a bracket. It hides rNDC versus PCIe versus OCP 3.0 versus FlexibleLOM. It hides RJ45 versus SFP+ if the cages are cropped. It hides Dell firmware versus Intel firmware. It hides an X710-DA4 sold as a DA2, which matters in a 1U. It hides a 57810 under the words Dell 10Gb dual-port. It hides a ConnectX-3 under the words 40GbE Mellanox, which will not produce a vmnic on ESXi 8. It hides a missing low-profile bracket.
It also hides the subsystem ID. Two cards with 8086:1572 on the main ID can differ on the subdevice, and the HCL line is the full ID. If you are matching a cluster that is already on a named VIB, send the PCI ID from a working host, lspci or the ESXi device list, and we will compare it to the sticker on the spare. We test that the card enumerates and links on the firmware it has. We do not flash it onto a different vendor's image, and we do not claim VMware support for a combination your image has not booted.
What to send us
Send the server, the ESXi build, and the slot on WhatsApp or Messenger. We will say whether the card on hand is a PCIe X710, an rNDC, or an OCP module before it ships from Hong Kong.
- The chassis and the generation. R740, R750, R760, DL380 Gen10, DL380 Gen11, or the board name. That tells us rNDC, FlexibleLOM, or OCP 3.0.
- The ESXi build, not just the major version. 7.0 U3 and 8.0 U3 are different driver lists. If you are staying on 6.7, say so. An X520 can still be honest there, and it is a bad buy for a host you plan to move to 8.
- The media. SFP+, SFP28, 10GBASE-T, or QSFP. Name the switch if the optic has to be coded. A generic SR module is a normal partner for a retail X710. It is a gamble in a Dell OS10 or an Aruba CX port.
- The PCI ID if you are replacing a known-good vmnic. Vendor, device, subvendor, subdevice. A photo of the sticker is the next best thing.
- The bracket. 1U needs low profile on a PCIe card. An OCP module has no bracket to swap.