RAID cache batteries on used controllers

A dead H710 battery or H730 supercap leaves the virtual disk in write-through. The pack is not interchangeable, and a photo of the holder does not show the log.

A RAID controller with a dead cache battery still brings the volume online. The disks look healthy. Every write is slower than the card you thought you bought. That is write-through. The controller waits for the disks before it acknowledges the write, because nothing is left to protect the cache. If you bought the card for write-back, the pack is half the order. A photo of a black module in the carrier does not show the charge state, and it does not show whether the module even belongs to that card.

We sell tested controllers from Hong Kong with the pack that is actually attached, and we read the log before they ship. A loose battery with no controller model is how the wrong generation arrives. The connector changed every time Dell and HPE changed the cache design. ZFS does not want any of these packs. If the pool is ZFS, buy an HBA in IT mode and skip the battery. The pages below are for hardware RAID that you intend to leave as hardware RAID.

Write-through is the symptom

Write-back means the controller acknowledges the write when the data hits protected cache. The disks catch up later. That is why a healthy H730P or P408i-a feels quick on a RAID 5 or RAID 6 of hard drives. Write-through means the acknowledge waits for the platter or the SSD. The virtual disk stays online. The latency goes up, and a database notices before a file copy does. RAID 10 feels the change less than RAID 5, and it still feels it.

perccli on Dell shows the battery or the cache vault as replace, failed, or missing, and the virtual disk stuck in WT. ssacli on HPE shows a failed capacitor or a failed Smart Storage Battery, and the cache drops to write-through or disables itself. Those lines are the test. A green LED on the canister is not. Learn cycles complicate the reading. A PERC will discharge and recalibrate the pack on a schedule, and write-back can drop to write-through for the duration. A pack that returns to write-back after the learn is a pack that still works. A pack that stays failed after the learn is a pack you replace.

H710 lithium packs

On the H700, H710, and H710P, common in an R710 or an R720, the cache is DRAM on the card and the protection is a lithium pack on a cable. The H710P is the one with the larger cache, 1GB, and it wants that pack healthy. The H310 has no cache and no battery. People still order a battery for an H310. There is nowhere to plug it in. The H710 mini mono and the adapter version use the same generation of pack. They do not use the later supercap.

Those lithium packs are old. A card pulled in the 12G era is a decade past the date code we like to see. Plenty of them fail the next learn cycle, even if they reported optimal on the day they were pulled. When the pack is failed, perccli shows the battery as replace and the virtual disk stuck in WT. A swollen pack is scrap. The cells leak onto the cache module and take it with them. If the shrink wrap is split or the pack is pillowing, do not cable it to a good cache DIMM to see what happens. The corrosion shows up later as a cache error, and the module goes with the pack.

The external cousin is the H810. Same era, same idea, a battery for a cache that sits on an external RAID card. An H810 pack is not the thing you cable to an H730, and an H710 pack is not a spare for an H810 unless the connector and the card generation actually match. Match the pack to the model printed on the card, not to the word PERC battery in the title.

Do not force write-back

Some previous owner forced write-back with no battery. The option has names like No Battery Write Cache, or a force flag in the virtual disk policy. Turn that off. A power cut mid-stripe on RAID 5 or RAID 6 can corrupt a volume that otherwise looked fine. The controller already told you it cannot protect the cache. Forcing the acknowledge does not create a battery. It creates a window.

RAID 10 is not a free pass. A torn write that the controller acknowledged can still land in the filesystem even when the mirror would have saved a disk failure. The symptom is not always a foreign configuration. Sometimes the volume mounts and the database is simply wrong. If the log shows forced write-back, clear the policy before you trust the array, and plan on a backup you made before the move. We do not ship a card with forced write-back left on. If a used card arrives that way from somewhere else, treat the volumes as dirty until you know otherwise.

After you fit a good pack, write-back can stay off for hours while an H710-era card charges and runs a learn. Benchmark the next day. A slow array on the afternoon of the swap is not proof the new pack is dead. A slow array the next morning, with perccli still showing WT, is.

H730 and H740 flash-backed cache

H730, H730P, and H740P use flash-backed cache. A supercap stores enough energy to destage DRAM into NAND when the server loses power. That pack is a different part from the H710 battery, with a different connector. The cache itself is a flash module on the card, not only a DRAM DIMM. No module means no cache, pack or otherwise. Some listings include the plastic holder and omit the module. The photo looks occupied. The card behaves like an H330.

The H730 and H730P are the 13G cards, and the mini mono fits the storage slot shared with 14G, so an H730P mini can move from an R730 to an R740. The pack still has to be the H730 generation. The H740P is the 14G card. Its supercap is another part, often on a cable to a holder in the chassis rather than a block that happens to look like the H730 pack in a top-down photo. An H740P mini does not take an H710 lithium pack, and it does not take the H730 supercap just because both are black. The H330 and the HBA330 have no cache socket. A battery in the same box is spare weight.

The external cards follow the same break. An H830 is the 13G external RAID card, flash-backed, not a lithium H810. An H840 is the 14G external card. Order the pack for the card you have, in the same shipment, so the connector can be checked before it leaves. A loose RAID battery with no controller model is how an H700 pack arrives for an H730.

H755 and the 15G pack

15th-gen Dell dropped the mini mono. The H755 and the HBA355 live in a front bay or on an adapter, with a different carrier from the R740. The H755 is the cache RAID card. The HBA355 is the passthrough card and does not grow a battery because you want write-back. There is no write-back on an HBA. People order an H755 supercap for an HBA355 because both say 15G on the listing. The HBA has nowhere to put it.

The H755 pack does not fit an H740P, and an H740P pack does not sit in an R750 front carrier. The cable length and the latch changed with the chassis. A 16G R760 storage layout changes again. A cache pack from an R750 front controller is not a universal Dell battery, and a slimline NVMe backplane does not use it at all. If the volume that is slow is sitting on NVMe behind a retimer, a RAID battery is the wrong part. Say the chassis. R720, R740, and R750 are three packs.

Supercaps fail differently from lithium packs. They rarely pillow and leak. They fail the learn, they fail open, or they fail short and the card disables the cache to protect itself. A visually perfect H730 pack from 2017 can still be at the end of its life. The log is the test. We will read it. A date code is a hint, not a pass.

HPE capacitors and the chassis battery

HPE did this in two layers, and the layer is what the listings omit. Older Smart Array cards, a P420 and a P440, use a capacitor module on or cabled to the card. ssacli reports a failed capacitor, and the cache disables. That module is not a Dell pack with an HPE label. A Gen9 capacitor does not plug into a P408i-a.

Many DL380 Gen9 and Gen10 chassis also have a Smart Storage Battery, a separate pack in the chassis that backs the NAND on the controller. On a Gen10 P408i-a or P816i-a, the cache you bought the card for often depends on that chassis battery. A controller pulled bare, without the battery the original chassis used, comes up in write-through even when the card itself is healthy. Replacing only a small module on the card misses the chassis battery. Replacing only the chassis battery misses a dead module on the card. Ask which one the log is complaining about. ssacli ctrl all show config detail is the text we want, not a screenshot of the cache ratio slider.

An E208i-a has no cache socket. A battery will not add RAID 6 and it will not add write-back. The P408e-p is the external card, and its backup part is still not a Gen9 capacitor and not a P408i-a module you happened to have in a drawer. Gen10 Plus and Gen11 move the controller again. The Gen11 MR416i-o is a MegaRAID module in the o slot. Its cache backup is not a Gen10 Smart Storage Battery transplanted into a Gen11. A P408i-a does not fit that slot, so the pack that came with it does not become the spare.

MegaRAID CacheVault

A Broadcom or LSI 9361-8i uses CacheVault. The flash module is on the card. The supercap is on a short cable. No supercap, no protected cache, and the virtual disk sits in write-through. The 9380-8i8e is the same generation with internal and external ports. A loose supercap from a different MegaRAID series is not automatically the mate for that flash module. The connector and the module revision have to match. A 9460-16i and a 9560-16i use later CacheVault parts. They do not take the supercap from a 9361 just because both are Broadcom and both have a two-wire lead.

The HBA cards do not have this socket. A 9300-8i, a 9400-16i, and a 9500-16i have no cache and no pack. If a listing shows a supercap next to a 9300, the supercap belongs to a different card, or the card is not a 9300. A 9460 photographed from the bracket end looks like a tri-mode HBA until you see the cache connector. Buy the pack for the RAID card you are keeping. Do not buy a pack to turn an HBA into a RAID card. It will not.

What the log can say, and what a photo cannot

Used packs lie about the charge they had on the day they were pulled. Ask for the controller log. You want a line that says the battery or capacitor is healthy, and that the logical drive is in write-back if write-back is why you bought the card. On Dell that is perccli, battery or cache vault optimal, virtual disk cache policy WB. On HPE that is ssacli, cache status OK, capacitor or Smart Storage Battery OK. A pack that is missing, failed, or learning is not a pack we describe as healthy.

The photo hides the date code, the swell, and the empty socket under the holder. It hides an H710 lithium pack in the same frame as an H730 because both are black rectangles with a cable. It hides a chassis Smart Storage Battery that was left in the old DL380. It hides forced write-back. It hides a cache DIMM that was removed and sold separately, which is common when someone parts out a controller. Confirm the cache module is actually on the card. Quote the card and the pack together so the connector matches.

We do not promise a used lithium pack will last three years. A pack is a wear item. Supercaps from the 2016 to 2019 pulls are in the window where a pass today can still be a fail next quarter. What we can do is ship a controller whose log, on our bench, shows the pack healthy and the policy on write-back, and we can tell you when the pack is absent. Firmware locks are a separate problem. A Dell pack does not become an HPE pack, and we do not cross-flash the controller to make a connector fit.

What to send us

Ask on WhatsApp or Messenger for the PERC or Smart Array model and a log that shows the cache pack healthy. If you are buying the card from us, we will read that log on the unit we ship. Freight from Hong Kong is quoted with the controller.

  • The controller model printed on the card. H710P, H730P, H740P, H755, H830, P440ar, P408i-a, 9361-8i. Mini, adapter, or front-bay carrier. The chassis if it is a Dell or an HPE, because the cable length follows the chassis.
  • What the log says today, if the card is already in the server. WB or WT, and the battery or capacitor line. A forced write-back flag if you see one.
  • Whether the cache module is on the card. A holder with no DIMM or no flash module is no cache.
  • Whether you want the chassis battery too. On a DL380 Gen10 that is often the part the P408i-a is actually using.
  • If the workload is ZFS or TrueNAS, say that instead. The right quote is an IT-mode HBA, not a fresher pack for a RAID card you are about to take out of the path.

All guidesFAQContact