HPE Smart Array on Gen10
The suffix on a P408i-a is the slot. A Gen10 modular card does not fit Gen10 Plus or a Gen11 -o bay, and a P-series board with an empty cache socket loses RAID 6.
HPE prints the slot in the suffix. On a Gen10 ProLiant that suffix is most of the compatibility, and it is the part listing titles crop first. A P408i-a and a P408i-p can share a feature list and still be useless in each other's chassis opening. We sell used Smart Array cards from Hong Kong against the server you already have. The iLO product name comes before the price.
Gen10, Gen10 Plus, and Gen11 are three controllers. The front of a DL380 looks the same in a bad photo. The modular connector does not. A Gen10 P408i-a does not fit a Gen10 Plus, and it does not fit a Gen11 bay whose suffix is o. People order the Gen10 card because the title said DL380 and the sticker said P408. The board arrives, the socket is wrong, and the bays stay empty.
The suffix is the slot
On a DL380 Gen10 or a DL360 Gen10 the common controller is the P408i-a. The i means internal SAS. The a means the type-a modular slot on the motherboard, the dedicated storage socket, not a PCIe riser. A P408i-p is the stand-up PCIe card with a similar RAID set. It will not plug into the modular slot. The -a card will not screw into a riser. If your photo of the board shows an empty modular socket, you want the -a part. If the planar has no modular socket and the riser is where the last controller lived, you want the -p part. Towers such as an ML350 Gen10 are the usual case for the stand-up card. Check the board you have before you match a DL380 listing.
The e means external. A P408e-p is the PCIe card for a shelf, a D3700 or a D3600, with SFF-8644 outside. It does not run the internal bays by itself. An E208e-p is the entry version of that external card. Ordering an external controller because the word P408 matched, then finding the front cage still dark, is a ticket we see on both 8-bay and 24-bay boxes. Internal and external are different FRUs even when the RAID levels match.
Blades are another suffix. A P408i-m is the mezzanine for a BL460c Gen10. It looks like a small Smart Array in a parts photo and it does not seat in a DL380 type-a slot. Synergy and Apollo modules are their own connectors again. A DL part number is the wrong harvest for those chassis. The suffix on the label is the whole check. A cropped photo that only shows P408 is how the wrong metal gets bought.
E208, P408, and P816
The E208i-a is the cheap Gen10 option. There is no cache socket. RAID 0, 1, 5, and 10. RAID 6 is absent, and so are 50 and 60. It is a fair card for a boot mirror of two SATA or SAS disks. It is the wrong card for a wide RAID 6 of large nearline drives. The E208i-p is the same entry controller in a PCIe bracket. Eight internal lanes, SAS 12Gb. People buy it because the price undercuts a P408, then discover the RAID level they already planned is missing from the menu in the Array Configuration Utility.
The P408i-a is the card most DL380 Gen10s shipped with when the build had a real array. The SR part includes flash-backed cache, commonly 2GB, clipped onto the controller. With that module fitted, RAID 0, 1, 5, 6, 10, 50, and 60 are available, plus HPE's RAID 1 ADM and 10 ADM. Those ADM levels are an HPE layout. A volume built that way does not import onto a Dell PERC. Stay on Smart Array if the logical drive has to live. Without the cache module the P-series controller loses RAID 5, 6, 50, and 60, and it loses write-back. The board can still mirror. It will not build the parity volume you counted on.
The P816i-a is the high-port Gen10 part. Sixteen internal SAS lanes, and the cache module on the SR card is commonly 4GB. It is the usual controller in a loaded 24-SFF chassis that is direct-attached rather than sitting entirely behind one expander. It still wants its own cache module. A P408i-a can see more than eight drives through an expander backplane. You share the eight lanes. That is fine for a shelf of spinning disks. It is a tight pipe for a cage of SSDs. If the backplane sticker is direct-attach and the bay count is sixteen or twenty-four, the P816i-a is the card that has the ports. A second P408 only helps when the chassis was cabled for two controllers. It does not split a single expander by wish.
Lane width on the host side still matters for the -p cards. A P408i-p wants an x8 electrical slot. It will enumerate in a narrower slot, and a cage of SSDs will then contend. In a 1U the bracket has to be low profile. We ship the bracket that is already on the card. Say so if the riser is full height and the photo shows a short bracket.
Cache module and the Smart Storage Battery
The cache is a separate piece of hardware from the RAID ASIC. On a P408 or a P816 the flash-backed module clips onto the controller. Used listings sell the board with an empty socket often enough that we ask before we quote write-back or RAID 6. The Array Configuration Utility then refuses the RAID level, or it builds the logical drive and leaves the cache disabled. A photo of the heatsink does not show the socket. Ask for a picture of the clip-on module, or a line from ssacli that names the cache size.
The Smart Storage Battery is a second part, and it usually lives in the chassis rather than on the card you were photographed. One battery, cabled from the front or the midplane of a DL380 Gen10, backs the controller. A second Smart Array in the same server is designed to share that battery. A failed battery drops cache to write-through, or disables it, on every controller that battery backs. ssacli reports the capacitor state. A black module in a carrier is not that report. Ask for the line that says the battery is healthy if write-back is why you are buying the P-series card.
The Gen9 capacitor does not plug into a P408i-a. A Dell H710 lithium pack does not plug in either. Match the pack to the controller family. Gen10 batteries and Gen9 batteries are different FRUs with different cables. A loose battery with no controller model on the quote is how the wrong pack arrives. We would rather sell the card and the battery together than ship a board and let you find write-through on a Saturday.
Write-through is the failure mode people miss, because the logical drive still comes online and the disks look healthy. The controller waits for the media before it acknowledges the write. RAID 6 of large 7.2K disks feels worse than the raw spindle time. RAID 10 feels it less, and a database still feels it. Do not force write-back with a failed battery. A power cut mid-stripe is a corrupt volume. After a good battery is fitted, give the pack time to charge before you benchmark. A swollen or leaking pack is scrap. It takes the cache module with it.
This is a different fault from a missing cache module. A missing module on a P408 or a P816 removes RAID 5, 6, 50, and 60. The E208 can still build a RAID 5, because that card never had a cache socket, and it still cannot build a RAID 6. A dead battery on a P-series card leaves the RAID levels in place and takes write-back away. Read which fault you actually have before you buy a second controller. iLO and ssacli both show it. The heatsink photo shows neither.
Gen9 cards stop at Gen9
Gen9 is the previous plug. A DL380 Gen9 uses a P440ar in the flexible smart-array slot, SAS 12Gb, with its own cache module. A P840ar is the wider Gen9 card. An H240ar is the Gen9 HBA-class part, no cache, the one people used when they wanted disks passed through on that generation. None of those boards fit a Gen10 type-a socket. The P440ar cache module does not clip onto a P408i-a. The cables on a Gen9 harness are a different length and often a different dressing from the Gen10 bay.
Gen9 and Gen10 both say Smart Array on the silkscreen, and both are 12Gb. That is where the overlap ends. A Gen9 pull is the right spare for a Gen9 chassis you are keeping alive. It is the wrong spare for the DL380 Gen10 on the bench. iLO 4 is Gen9. iLO 5 is Gen10 and Gen10 Plus. If the management page says iLO 4, stop looking at P408 listings.
Firmware on these cards is an HPE package, delivered through the Service Pack or iLO. We sell the card as it left the donor chassis. We do not flash a generic image, and we do not flash a Smart Array toward IT-mode LSI firmware. If a drive you add is newer than the controller firmware, updating it is your maintenance window on that ProLiant. A cross-flash is how the board loses the identity iLO expects.
Gen10 Plus uses a different modular card
Gen10 Plus is Ice Lake. A DL380 Gen10 Plus or a DL360 Gen10 Plus takes 3rd Gen Xeon Scalable on LGA4189, still DDR4, with PCIe 4.0. A Gold 6330 fits. A Gold 6248 does not. The modular storage connector changed with the planar. A Gen10 P408i-a does not seat. Ordering one because the bezel still says DL380 is the most expensive mistake on this page.
HPE split the controller brands on Plus. MR416i-a and MR216i-a are the MegaRAID side, Broadcom silicon, and on many Plus backplanes they are the tri-mode parts that can see SAS, SATA, and NVMe. SR416i-a is the SmartRAID side, the Microchip line that continues the old Smart Array management style. The suffix is still -a on those modular cards. The socket is not the Gen10 type-a socket. A P408i-a and an MR416i-a are not two stickers on one board.
The tools follow the brand. Classic Smart Array and the SR cards are what ssacli knows. MR cards want the MegaRAID tool chain. A how-to written for a P408i-a will not click through on an MR416i-a. Read the sticker in iLO before you follow a Gen10 guide on a Plus chassis. Cache still matters. An MR or SR card quoted without its cache module is the same class of miss as a P408 with an empty socket. Ask. The battery in a Plus chassis is the Plus part, not the Gen9 capacitor and not a loose Gen10 battery from a different cable length.
Cables moved on the tri-mode builds. Gen10 SAS harnesses are mini-SAS HD, SFF-8643. A Plus backplane that carries NVMe often wants slimline SFF-8654 leads back to the controller or the motherboard. Reusing the Gen10 SFF-8643 bundle in a Plus lid is how a card that posts still leaves half the bays dark. The backplane part number is the document. The bay count printed on the bezel is not.
Gen11 uses the o suffix
Gen11 moves the storage module again. DL360 Gen11 and DL380 Gen11 take 4th Gen Xeon Scalable, Sapphire Rapids, and 5th Gen, Emerald Rapids, on LGA4677 and DDR5. iLO 6 is the management controller. A 4th Gen Gold 6430 and a 5th Gen part such as a Gold 6526Y are both Gen11 CPUs only when that board's firmware lists the generation. Sharing LGA4677 does not mean a first-wave Gen11 BIOS will take Emerald Rapids. The RAID card does not fix that.
The suffix on the Gen11 storage module is o. MR416i-o and MR216i-o are the parts you will see, along with SR modules in the same form factor. The o is an OCP-style storage module. It is a different opening from the OCP 3.0 NIC slot on the same chassis. An OCP network card does not become a RAID controller, and a Gen10 -a card does nothing in the -o bay. A Gen10 Plus MR416i-a does not drop into a Gen11 -o carrier either. Three generations, three connectors, one bezel shape in the photos.
NVMe boot on Gen11 is often a separate small module, the NS204 class, two M.2 devices for the OS. That module is not the bay controller. It does not run the front cage, and a P408i-a does not replace it. Front bays still follow the backplane. A tri-mode -o card in front of a SAS-only backplane, or a SAS personality in front of a pure NVMe backplane, leaves the same dark bays as the Dell front PERC mismatch. Read the backplane. DDR5 on this generation, including the faster bins 5th Gen can train, does not change the storage connector.
Gen12 is the following platform, Xeon 6, a newer iLO, and another planar. Do not assume a Gen11 MR416i-o carries over because the product line is still called DL380. Send the iLO product name. We match the module to that name. Guessing from a 2020 P408 listing is how the wrong connector shows up in 2026.
AMD ProLiant tracks the same suffix rules on a different socket. A DL385 Gen10 is EPYC on SP3, DDR4, and it uses the Gen10 type-a slot. A P408i-a that fits an Intel DL380 Gen10 is the shape that fits that AMD Gen10. A DL385 Gen10 Plus is Milan-era EPYC and wants the Plus MR or SR modular card. A DL385 Gen11 is Genoa-class EPYC 9004 on SP5 and DDR5, and the storage module is the -o part. Bergamo parts that belong in a Gen11 density build still use that Gen11 module. Turin, EPYC 9005, is a later platform. Send the iLO name before you pair a Gen10 P408i-a with an AMD chassis whose bezel looks familiar.
Cables, expanders, and external shelves
Internal SAS on a Gen10 P408i-a or E208i-a is SFF-8643. The harness length is part of the chassis, not part of a universal HPE cable. An 8-SFF direct backplane, a 16-SFF, and a 24-SFF with an expander are different dressings. Moving a known-good P408i-a from a donor DL380 into your DL380 still means checking that the bay cable reaches the modular slot and that the port count matches. The 24-SFF expander config can run from eight lanes. The direct-attach 24-SFF config cannot. The lid diagram, or the backplane sticker, is the authority. A listing that says 24-bay capable is describing some chassis, not necessarily yours.
External shelves use SFF-8644. A P408e-p in a riser, cabled to a D3700, is the 12Gb path. A 6Gb D2700 or D2600 wants the older external plug and will not grow 12Gb because the card is newer. One enclosure management module will run the shelf on a single path. Dual domain wants both modules and dual-port SAS disks. SATA disks in that shelf are single-ported unless the carrier has an interposer. The Smart Array will build a logical drive either way. The second path is the part that quietly does not exist.
Sector size still applies. 512e and 4Kn do not belong in one logical drive. Match a replacement member to the survivors. Third-party SAS disks work behind these controllers. iLO may not show the same predictive pages it shows for an HPE-branded drive. That is normal on a used disk. It is not a reason to flash the controller. Carriers are a separate part. The Gen10 SFF carrier is the Smart Carrier family. A Gen9 tray looks close in a photo and latches wrong. The controller can be perfect and the bay still fails the insert.
NVMe U.2 bays on a Gen10 need their own backplane and cables. A P408i-a does not speak those lanes. Gen10 Plus and Gen11 tri-mode cards can, when the backplane is the tri-mode one and the slimline cables are present. Empty bays in a photo do not tell you which wiring you have. If you need the bays to take NVMe, say so. We will not quote a SAS P408i-a into that job.
HBA mode is a setting
Later P408 firmware can present raw disks. HPE calls it HBA mode or mixed mode, depending on the revision. Mixed mode can keep a logical drive for boot and hand the rest of the disks through. That is a setting in the firmware the card already has. It is still a Smart Array. ssacli still owns it. It is not an LSI IT-mode HBA, and it does not become one because a forum post said to flip a switch.
Shops running TrueNAS or ZFS usually skip that mode. They want each disk, with its serial, on a card whose only job is pass-through. On a Gen10 that has a free PCIe slot, that card is a 9300-8i or similar already on IT firmware, from the RAID and HBA list. The modular P408i-a can come out, or it can stay for a boot mirror if you prefer, and the pool disks move to the HBA. The cables have to move with that decision. The factory harness lands on the type-a slot. An HBA in a riser needs SFF-8643 leads that reach the riser.
We sell the Smart Array as listed. We do not flash it to IT firmware, and we do not flash an MR or SR module to a generic Broadcom image to chase a feature. Order the behavior you need. An E208i-a will not grow RAID 6 because someone flashes it. An empty cache socket on a P408 will not grow a cache module from a firmware file. The metal has to be in the box.
Gen9 H240ar owners hit the same wall one generation earlier. That card is the pass-through option for Gen9. It is not a donor you reflash into a P408, and it does not fit the Gen10 slot. If the pool is ZFS and the chassis is Gen10, say so on the quote. The answer is an HBA, or a P408 left in the HBA mode it already supports, and we will tell you which of those we actually have.
What the listing photo hides
The heatsink and the HPE logo travel from Gen9 to Gen11. These are the lines a top-down photo leaves out:
- The full suffix. P408i-a, P408i-p, P408e-p, P408i-m. Internal, external, modular, mezzanine.
- E208 versus P408 versus P816. The RAID levels and the port count change with that letter and number.
- The cache module. An empty socket means no RAID 6 and no write-back on a P-series card.
- The Smart Storage Battery, which is often still in the donor chassis, outside the crop.
- Gen10 versus Gen10 Plus versus Gen11. The iLO product name is the proof. The bezel is not.
- The bracket on a -p card, low profile or full height.
- Cables. SFF-8643 for Gen10 internal SAS, SFF-8644 for the external card, slimline on later tri-mode backplanes.
A tested note means the card posted and saw disks in a compatible ProLiant. It does not mean the cache is populated, the battery is healthy, or the module will seat in the generation you left off the message. iLO's product string is one line. Send it.
What to send us
Message the ProLiant on WhatsApp or Messenger before you pay for a P408 from the wrong socket. A screenshot of the iLO system page, plus a photo of the current controller label, is enough. We match the card, the cache, and the battery, and we ship from Hong Kong.
- The iLO product name: DL380 Gen10, Gen10 Plus, or Gen11, or the AMD DL385 equivalent.
- The suffix you need: -a, -p, -e, or -o.
- E208, P408, or P816 on Gen10. MR or SR on Plus and Gen11.
- Whether the cache module and the Smart Storage Battery have to be in the box.
- Bay count, expander or direct-attach, and SAS versus NVMe.
- ZFS or TrueNAS if the disks have to stay raw. We will quote an HBA instead of a flashed Smart Array.
A P408i-a with its 2GB module and a healthy battery is the right spare for a Gen10 DL380 that already uses that slot. It is the wrong spare for a Gen10 Plus MR416i-a and the wrong spare for a Gen11 MR416i-o. Send the suffix and the product name together. The bezel is not enough.