Guides
HBAs to buy for a ZFS or TrueNAS build
Pick the HBA from the backplane you already have: 9300 IT for SAS disks, 9400 or 9500 when a bay is U.2, and a 9460 or H730 left off the pool.
The pool already decided the card. ZFS wants each disk as its own device, with the serial that is printed on the lid, and it wants SMART without asking a RAID controller for permission. A hardware RAID card hides that disk behind a virtual drive. The resilver then belongs to the card, and a failed member is a foreign-config problem instead of a tray you can pull. Buy an HBA that is already in IT mode. We sell the firmware the card has. We do not flash a RAID card over to IT as part of the sale, and a bad flash is a brick we cannot recover from here.
Late 2026 has not retired the 9300. It has added chassis that make the old default wrong. An R760, an HPE Gen11, a Supermicro H13 with EPYC Genoa or Turin, and a Xeon 6 board all have PCIe slots a 9300 will run in. They also have E3.S or U.2 bays a 9300 will never light, and an OCP 3.0 slot that is for the NIC, not for the HBA. Start from the backplane label, then pick the card.
IT firmware is the filter
IT firmware is the initiator-target image. The card presents every attached SAS or SATA disk as its own SCSI target. Linux binds mpt3sas on a 9300 or a 9400. TrueNAS SCALE is Linux, so that is the driver you see there. TrueNAS CORE still binds mpr on FreeBSD. The disk screen shows the model and the serial from the drive. A failed member is a failed disk. There is no cache module and no battery, which is what you want in front of ZFS. The HBA does not acknowledge writes on its own.
IR firmware is the integrated RAID image on some of the same boards. It builds RAID 0, 1, and 10, and it hands the operating system a virtual disk. A single disk configured as a one-drive RAID 0 is still IR. People turn that on because a menu called it JBOD, then spend a weekend wondering why the serial does not match the tray. Both images can leave the same model number on the silkscreen. The listing has to say IT before the card belongs in front of a pool.
The IT packages that have been running in NAS boxes for years on the 9300 are the 16.x line, often called P16. Newer HBAs have their own HBA firmware trains. We do not wipe a working IT image to build a hardware mirror, and we do not take an IR card and promise it will be IT by the time it reaches you. Order the behavior the pool needs. If you actually want a hardware mirror, say so, and the card stays a RAID card.
9300 and 9305 when the disks are SAS or SATA
For a chassis full of hard drives, or a modest set of SATA SSDs, the 9300-8i is still the card we ship most. The chip is the SAS3008. The slot is PCIe 3.0 x8. Two SFF-8643 connectors bring out eight lanes at 12Gb. Eight bays on a direct-attach backplane, or a whole expander cage from one of those connectors. The same board has been silkscreened LSI, Avago, and Broadcom. The logo does not change the connector or the firmware split.
Past eight direct bays the SKU changes. The 9300-16i brings out sixteen lanes on four SFF-8643 connectors. It is still a PCIe 3.0 x8 card. You bought ports. You did not buy a wider bus. Sixteen spinning disks are a comfortable load. Sixteen SATA SSDs share that same link, and the pool will not scale like sixteen independent drives. The 9300-16i is two SAS3008 controllers behind a PCIe switch, so lspci shows two HBAs, and the heatsink wants real airflow. The later 9305-16i is a single SAS3216, sixteen ports, cooler, same job in front of a hard-drive pool. The 9305-24i uses the SAS3224 and six SFF-8643 connectors, for a direct-attach cage a 16-port card still cannot fill. A long green card with four mini-SAS HD ports can be a 9300-16i or a 9305-16i. Ask which string is printed on the board.
The 9300-8e is the external card. Two SFF-8644 connectors face the rear bracket, for a disk shelf such as a Dell MD1400 or an HPE D3600. An internal SFF-8643 lead does not fit an 8e. The 9300-4i4e is one internal connector and one external connector, for a chassis that has a few internal bays and one shelf, after you have counted those four internal lanes honestly. None of these speak NVMe. A U.2 bay stays dark behind a 9300.
9207 and 9211 when the cables are already 8087
The 9207-8i is the older SAS2308 card. PCIe 3.0 x8, 6Gb link speed, internal SFF-8087 connectors. It is still a solid IT-mode HBA for hard drives and a small pool of SATA SSDs, if the backplane or the breakout cables in the chassis are already 8087. Skip it for a shelf of 12Gb SSDs. The link will come up at 6Gb, and you will have paid for a faster disk to run at the cable's speed.
The 9211-8i is SAS2008 on PCIe 2.0, also SFF-8087. It still runs disks. The 2TB caution you still see in old forum posts belongs to early firmware on this chip, not to a 9300. On a current IT image a large nearline disk is fine here too, but the slot is only PCIe 2.0 x8, so a pack of SSDs feels it. The 9207-8e is the external 6Gb card, SFF-8088 on the bracket, for an MD1200 or an HPE D2600. A 12Gb 9300-8e does not take that 8088 plug.
An SFF-8087 shell does not seat in an SFF-8643 port. A directional 8643-to-8087 cable exists. Confirm the direction before it ships. A title that says mini SAS covers both generations, and a photo of a black cable does not show the shell. If the backplane label says 8087, buy the 6Gb HBA. Do not buy a 9300 and hope the old harness stretches.
9400 when a bay is U.2
The 9400-8i and 9400-16i are the first Broadcom HBAs that are tri-mode. The chips are the SAS3408 and the SAS3416. They are 12Gb SAS, they still speak SATA, and on the right backplane they also speak NVMe. The slot is PCIe 3.1 x8. Connectors stay SFF-8643, two of them on the 8i and four on the 16i, which is why people treat a 9400 as a faster 9300. It is not faster on a shelf of Seagate Exos drives. It is the card you buy when a bay is U.2 and you mean to use it.
Tri-mode is a property of the backplane as much as the card. A SAS-only expander does not become an NVMe fabric because a 9400 is plugged into the uplink. The U.2 bays need a tri-mode backplane, the right sideband, and a cable that carries the NVMe lanes. A 9400 in front of a classic BPN-SAS3-826EL1 runs the SAS and SATA disks and leaves a bolted-on NVMe bay dark. They also run warm. A 9400-16i under a blank in a 1U needs airflow across that heatsink, the same way a 9300-16i does.
The external twin is the 9400-8e, SFF-8644 on the bracket, for a shelf that is still SAS. Buy it when you already know you want tri-mode silicon in that generation. For a plain MD1400 full of nearline disks, a 9300-8e on IT firmware is the simpler spare, and a failed port at 2 a.m. is an easier replacement.
9500 and 9600, and the SlimSAS cable
The 9500-8i steps up to PCIe 4.0 and stays tri-mode. The chip is the SAS3808. The 9500-16i is the SAS3816. Both are more card than a pool of hard drives needs. Buy one when the backplane is tri-mode, the slot is actually Gen4 or Gen5, and you mean to use the NVMe lanes. The connector change is the order that goes wrong. A 9500-8i has one SFF-8654 SlimSAS plug, not two SFF-8643 plugs. A 9500-16i has two SFF-8654 plugs. The SFF-8643 leads from a 9300 install do not seat. The card tests fine on our bench with the matching cable, and it looks dead in a chassis that still has the old harness.
The 9600 series steps up again, to 24Gb SAS, and stays tri-mode on PCIe 4.0. The 9600-16i is the HBA we get asked for when a new backplane is already SlimSAS and the disks are SAS4. A used pile in late 2026 is still mostly 12Gb expanders. A 9600 in front of an MD1400 links at 12Gb and costs more to replace. The same SlimSAS cable rule applies. Order the leads with the card if the drawer does not already have SFF-8654.
A Gen5 slot on an R760, a Gen11 ProLiant, or an SP5 board does not make a 9500 into a Gen5 card. The link trains at the card's generation. Hard drives do not care. A bay of Gen4 NVMe drives will care, and the PCIe x8 ceiling is still there. Sixteen fast NVMe drives belong on the platform's own retimers or on more than one tri-mode HBA, not on a single x8 uplink you hoped was infinite.
The MegaRAID numbers that sit next to them
The part that arrives in place of a 9300 is the 9361-8i. It is a MegaRAID card on the SAS3108, with a cache module and a CacheVault supercap. The connectors are also two SFF-8643 plugs, which is why a photo cropped at the bracket looks like a 9300-8i. The SAS3108 does not run 9300 IT firmware. The closer lookalike is the 9341-8i, a SAS3008 with no cache socket and a JBOD toggle in a RAID menu. That toggle is not the IT image. We sell a 9341 as a 9341.
The same trap repeats one generation later. A 9460-16i is tri-mode MegaRAID, cache and capacitor, not a 9400-16i. A 9440-8i is the smaller RAID card in that family. A 9560-16i is the PCIe 4.0 MegaRAID, not a 9500-16i. A 9670W-16i is the cache RAID card in the 24Gb generation, not a 9600-16i. The heatsink photo is how these get swapped. A cache socket, a supercap cable, or the word MegaRAID in the BIOS banner means the pool would sit on a virtual disk. Read the silkscreen. SAS3008 or SAS3408 on an HBA firmware line is the pass-through card. A cache DIMM on the board is MegaRAID even when the title says HBA.
Adaptec cards show up in the same search. An ASR-81605Z or an 8805 is a RAID controller with its own cache battery. It can be the right card for a hardware volume. It is the wrong card for a TrueNAS pool. We do not cross-flash Adaptec, MegaRAID, or PERC firmware onto an LSI IT package.
Dell HBA330, HBA355, and the PERC menu
Dell's HBA330 is a SAS3008 with Dell firmware, built as a passthrough card. In an R630, an R730, or an R740 it matches the storage slot and the factory cables. Disks show up as raw devices. TrueNAS and ZFS are fine with it. The Mini Mono version sits in the dedicated storage slot on 13G and 14G. It does not use a standard PCIe bracket, and it does not drop into a Supermicro or a generic tower. The HBA330 Adapter is the PCIe version. That one can move to a riser. It is still Dell firmware. Leave it on that firmware.
Two Dell names sit next to it and cause the bad orders. The H330 is a RAID card, no cache, RAID 0, 1, 5, and 10. A menu entry called HBA on some revisions is a Dell setting, and later revisions have removed it. The H730, H730P, H740, H740P, and H755 are cache RAID cards. Leave them on the virtual-disk work they were built for. A PERC toggled into an HBA setting is a menu option we would not build a pool on. OEM firmware revisions have removed that option before, and a virtual disk created last year does not become eight raw disks because the menu moved.
The HBA355 is the 15G passthrough card for an R650 or an R750. Different slot, different cables, often a front-bay carrier rather than a 14G mini mono. An HBA330 Mini from an R740 does not mount in an R750. An H755 is the 15G RAID card, not the HBA, even when both listings say Dell 15G storage. On a 16G R760 the storage layout changes again, with slimline cables and retimers for NVMe bays. A 9300 in a PCIe riser still runs a SAS backplane in that chassis. It does not run the E3.S bays.
HPE H240 and the Smart Array mixed-mode trap
HPE's H240 is SAS3008 silicon with HPE firmware, from the Gen9 era. It belongs in the ProLiant it came from. A retail 9300-8i in a free PCIe slot is the usual way to give a DL380 Gen9 or Gen10 a TrueNAS pool without relying on Smart Array mixed mode. We sell the H240 as an H240.
The Gen10 modular cards are a different product. A P408i-a, a P816i-a, and an E208i-a are Smart Array controllers. Mixed mode, or an HBA personality in the menu, still presents the logical-drive stack. It is not Broadcom IT firmware. A DL380 Gen10 that needs raw disks gets a 9300 or a 9400 in a PCIe slot, and the modular controller stays on the boot mirror or comes out so two controllers are not fighting the same backplane. The P408e-p is the external RAID card. It will run a D3700 as virtual drives. It is the wrong front end for a ZFS shelf. Order a 9300-8e or a 9400-8e on IT firmware instead.
Gen10 Plus and Gen11 change the slot again. The Gen11 storage module is the o form factor, an MR416i-o and the cards like it, and those are MegaRAID parts. A Gen10 P408i-a does not fit. An MR416i-o does not become an IT HBA because the pool is ZFS. The PCIe riser is still where the 9300 or the 9500 goes. Supermicro's AOC-S3008L-L8e leaves the factory on IT firmware. The trailing e means the IT image, not external ports. The AOC-S3008L-L8i is the IR image. Read the full string. Lenovo's N2215 is SAS3008 silicon, usually already on an IT image, often with a System x bracket. The ThinkSystem 430-8i is the next generation, a 9400-class HBA, and it should be ordered under that name.
Port count, expanders, and the slot
Each SFF-8643 connector is four lanes. On a direct-attach backplane that is four drives. An 8i feeds eight bays. A 16i feeds sixteen. A 24-bay expander chassis can run from one 8i, because the expander shares the pipe. A Supermicro BPN-SAS3-826EL1 is the common 12-bay 3.5-inch expander. A BPN-SAS3-846EL1 is the 24-bay version. One port lights the cage. Twenty-four hard drives do not fill four 12Gb lanes. Twenty-four SATA SSDs will. If the pool is SSD, use more uplinks or a direct backplane and a 16-port card, and treat the PCIe x8 slot as the next ceiling.
A direct-attach backplane has no expander. The Supermicro BPN-SAS3-826A needs three SFF-8643 cables for twelve bays. A 9300-8i has two connectors, so eight bays enumerate and four stay dark. The card is healthy. The fix is a 9300-16i, a 9305-16i, or a second HBA. The EL1 and the A boards look similar from the front of the chassis. Pull the label before you buy the 8i out of habit.
Use an electrical x8 slot. An open-ended x4 slot trains at x4, and eight SSDs then share half the bus. The disks test healthy and the pool looks slow. On a Dell, the riser matrix in the service manual is the page that says which slot is actually x8. Bracket height is the other physical check. A 1U wants the low-profile bracket on a 9300-8i. The 9300-16i is a full-height long card and often will not fit a 1U at all. A reverse breakout cable is the last silent failure. Four motherboard SATA ports on one end and one SFF-8643 on the other, plugged into the HBA, links nothing. A forward breakout, HBA to four loose disks, is the cable that works. A backplane with SFF-8643 sockets wants a straight 8643-to-8643 lead.
What the listing photo hides
The cropped photo shows two metal cages and a heatsink. It hides the silkscreen that says 9341, 9361, 9460, or 9560. It hides IR versus IT. It hides a missing low-profile bracket. It hides a 9300-8e when you needed internal ports, because SFF-8644 and SFF-8643 look similar if the photo is dark. It hides SFF-8654 on a 9500, which is a different shell from the cable in your hand. It hides a Supermicro AOC-S3008L-L8i sold under the word LSI, and an H330 sold under the word HBA.
It also hides the cable, which is usually a separate line and the part that decides whether Monday's install links. Ask for the cable in the same shipment if you do not already have the right leads, and say forward breakout only when the disks are loose. We test the card on a SAS backplane before it ships, on the firmware it has. We do not flash it to change that firmware. A card listed as IT is IT. OEM drive firmware is a separate surprise: some Dell and HPE SAS SSDs throw a fault LED on a plain 9300 even though they still speak SCSI. Generic Exos and Toshiba MG nearline disks rarely do this. If the pool is Dell-branded SSDs, say so.
Disks from a MegaRAID or a PERC can still carry array metadata. On IT firmware they usually enumerate. Wipe them before they join a pool. Array pulls are sharper. Disks from some storage shelves are formatted with 520-byte sectors. The HBA will see them. ZFS still wants 512 or 4096. A 16TB or 20TB Exos on P16-era IT firmware is a routine pool member. Mix of SAS and SATA on the same IT card is fine. Mix of SAS and SATA inside one vdev is a choice you should make on purpose. The HBA will not stop you. Dual-path shelves are a planned layout. Two copies of the same disk, added as two pool members, will wreck the pool. One HBA and one cable is the simple path. Two enclosure modules, both cabled, means multipath, and the operating system has to present one device per disk.
What to send us
Send the chassis and the backplane before we pick a card off the HBA shelf. A photo of the backplane label is enough. Message us on WhatsApp or Messenger with the list below, and we will quote the card that is already in the firmware the pool needs. Freight from Hong Kong is quoted with the shipment. We do not flash the card on the way out.
- The chassis and the generation. R730, R740, R750, R760, DL380 Gen10, DL380 Gen11, a Supermicro 826, or the board name. Say if the bays are SAS, U.2, or E3.S.
- The backplane. Bay count, expander or direct-attach, and the connector printed on it: SFF-8087, SFF-8643, or SFF-8654. If the disks live in a shelf, name the shelf. MD1200, MD1400, D3600, and a NetApp DS4246 are different cables.
- The workload. ZFS or TrueNAS means IT. A hardware mirror means IR or a MegaRAID, and those stay their own SKUs. Say if any disk is a 520-byte array pull.
- The bracket, the slot, and the cable. 1U or tower, whether you need a low-profile bracket, and whether you already own forward breakouts or 8643-to-8643 leads. A 9500 needs SFF-8654.
- The operating system, if the boot disk has to sit on this HBA. A lot of used IT cards have had the option ROM removed. The data path still works after the OS is up from a SATA DOM, a chipset SSD, or a Dell BOSS card.